WARNING
DISCONNECT POWER BEFORE RELAMPING OR WIRING THE FIXTURE.
READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION.
CAUTION
TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL AND LOCAL
ELECTRICAL/BUILDING CODES.
INSTALLATION AND MAINTENANCE OF THIS UNIT REQUIRES AN ELECTRICIAN OR CERTIFIED FACTORY TRAINED TECHNICIAN.
If an existing fixture is being replaced, remove it and note to which of the wires in the outlet box the fixture was attached. DO NOT SEPARATE
ANY OTHER WIRES THAT MAY BE IN THE BOX. DO NOT DAMAGE THE INSULATION OF OLDER WIRING. In regular circumstances the BLACK
wire will be the “Hot” lead and the WHITE wire will be the “Neutral” or “Common” lead. A GREEN or BARE COPPER wire is the “Ground”. In
older buildings, it is always good practice to reconfirm the polarity of the wiring.
NOTICE
The important safeguards and instructions outlined on this
sheet cannot cover all possible conditions and situations that
may occur. It must be understood that common sense, caution
and care are factors that cannot be built into any product.
Caution and care must be supplied by the person(s) installing,
operating and caring for this lighting fixture.
This fixture is designed to be mounted on a correctly installed
standard round or octagon box or a through wiring box with a
plaster frame. The box must be securely mounted to the
structure of the building. The crossbar and hardware supplied
should be used. Directly mounting the fixture to the outlet box
may make it impossible to correctly align the fixture.
FIXTURE PREPARATION
1. Remove the fixture, shade and parts bag(s) from the carton.
NOTICE:
Before discarding the carton, double check the contents
to make certain that all parts are found.
FIXTURE INSTALLATION
1. Thread the2 studs into the crossbar at the proper spacing.
Attach the adjustable crossbar to the outlet box.
(The green screw should face out.)
2. Adjust the studs so that they extend 3/16” beyond the back
of the fixture.
3. Fasten the ground wire to the green or bare copper wire
in the outlet box or the green screw on the crossbar.
WARNING
Never fasten the ground wire to the black or "hot" wire!
Failure to follow this instruction could result in serious
injury or death!
Outlet box
Green screw
Crossbar
Stud
End ball
Lamp
Arm
Glass
Ring
Canopy
Stem
Soft washer
Trim cap