Installation Guide

Page 1 of 2 300112ID
105-41 SHOJI INSTALLATION INSTRUCTIONS
WARNING
DISCONNECT POWER BEFORE RELAMPING OR WIRING THE FIXTURE.
READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION.
CAUTION
TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL AND LOCAL
ELECTRICAL/BUILDING CODES.
INSTALLATION AND MAINTENANCE OF THIS UNIT REQUIRES AN ELECTRICIAN OR CERTIFIED FACTORY TRAINED TECHNICIAN.
If an existing fixture is being replaced, remove it and note to which of the wires in the outlet box the fixture was attached. DO NOT SEPARATE
ANY OTHER WIRES THAT MAY BE IN THE BOX. DO NOT DAMAGE THE INSULATION OF OLDER WIRING. In regular circumstances the BLACK
wire will be the “Hot” lead and the WHITE wire will be the “Neutralor “Common” lead. A GREEN or BARE COPPER wire is the “Ground”. In
older buildings, it is always good practice to reconfirm the polarity of the wiring.
NOTICE
The important safeguards and instructions outlined on this sheet cannot cover all possible conditions and situations that may occur. It must be
understood that common sense, caution and care are factors that cannot be built into any product. Caution and care must be supplied by the
person(s) installing, operating and caring for this lighting fixture.
This fixture is designed to be mounted on a correctly installed standard round or octagon box or a through wiring box with a plaster frame. The
box must be securely mounted to the structure of the building. The crossbar and hardware supplied should be used. Directly mounting the
fixture to the outlet box may make it impossible to correctly align the fixture.
This fixture is supplied with a 4-piece stem. There is one 6” section, two 12” sections and one 18” section. This feature allows the fixture to be
mounted with a tem up to 48” in length in 6” increments.
This fixture is supplied with a swivel. By rotating the canopy the fixture may be mounted to an angled ceiling.
FIXTURE PREPARATION
1. Remove the fixture, diffuser, panels and parts bag(s) from the carton.
NOTICE:
Before discarding the carton, double check the contents
to make certain that all parts are found.
FIXTURE INSTALLATION
1. Determine the overall desired length of the fixture.
Assemble the stems one at a time onto the fixture leads.
Tape the ends of the leads to a stiff wire (coat hanger)
to aid in pulling them through the stems.
NOTICE:
Place the canopy onto the stem
BEFORE assembling the top stem section and swivel.
2. Attach the mounting ring to the outlet box.
(The green screw should face the floor.)
Back out the screws ½ turn to allow the ring to rotate.
3. Thread the studs into the mounting ring at the spacing that matches the mounting
holes in the canopy. Adjust the screws so they extend 3/16” beyond the canopy.
4. Cut off the excess ground and fixture wire 6” beyond the canopy.
Strip ½” of insulation from the ends of the wire. Twist the wire strands together.
Outlet box
Canopy
Swivel
Stem
Stud
Green Screw
Mounting ring
Coupling

Summary of content (2 pages)