7-9
Setting Procedure of Vertical Timing
7.3.3 Horizontal Timing (Course Adjustment)
The H-PHASE (COURSE) is used to set the horizontal timing. The settable range
depends on the format.
Settable Range
Refer to Table 7-2. The step is about 0.0741 μs.
Table 7-2 Horizontal timing settable range
Format H-PHASE [μs]
1125i/60 ±14.8148
1125i/59.94 ±14.8148
1125i/50 ±17.7778
1125p/30 ±14.8148
1125p/29.97 ±14.8148
1125p/25 ±17.7778
1125p/24 ±18.5185
1125p/23.98 ±18.5185
1125PsF/24 ±18.5185
1125PsF/23.98 ±18.5185
750p/60 ±11.1111
750p/59.94 ±11.1111
750p/50 ±13.3333
750p/30 ±22.2222
750p/29.97 ±22.2222
750p/25 ±26.6667
750p/24 ±27.7778
750p/23.98 ±27.7778
NTSC BB ±31.7778
NTSC BB+REF ±31.7778
NTSC BB+ID ±31.7778
NTSC BB+REF+ID ±31.7778
525i/59.94 ±31.7778
525p/59.94 ±15.8519
PAL BB ±32.0000
PAL BB+REF ±32.0000
625i/50 ±32.0000
625p/50 ±16.0000
Display the V-PHASE by using the [
5
] and [
6
] keys.
Press the ENTER key.
Press the ENTER key.
1.GL SETTING
t
GENLOCK TIMIN
2.GENLOCK TIMING
v
V-PHAS
3.V-PHASE R:2.997H
Display the GENLOCK TIMING by using the [
5
] and [
6
] keys.
2.GENLOCK MODE SET
u
F-PHAS
Press the ENTER key. Press the MENU key to cancel.
Sets the line by using the [
5
] and [
6
] keys.
The internal reference signal is displayed at the upper-right corne
r