Instruction manual

7-8
7.3.1 Timing in Frame Steps
The F-PHASE is used to set the timing in frame steps. The timing can be set in NTSC
and PAL formats. The settable range depends on the format.
Settable Range
NTSC: ±5 frames, in 1 frame steps
PAL: ±2 frames, in 1 frame steps
Setting Procedure of Timing in Frame Steps
7.3.2 Vertical Timing.
The V-PHASE is used to set the vertical timing.
The settable range depends on the format.
Settable Range
1125i, 1125p, 1125PsF: ±1125 lines, in 1 line steps
750p: ±750 lines, in 1 line steps
525i, 525p for NTSC: ±525 lines, in 1 line steps
625i, 625p for PAL: ±625 lines, in 1 line steps
Display the F-PHASE by using the [
5
] and [
6
] keys.
Press the ENTER key.
Press the ENTER key.
1.GL SETTING
t
GENLOCK TIMIN
2.GENLOCK TIMING
u
F-PHAS
3.F-PHASE R:2.997H
GL. FRAME
Display the GENLOCK TIMING by using the [
5
] and [
6
] keys.
2.GENLOCK MODE SET
u
F-PHAS
Press the ENTER key. Press the MENU key to cancel.
Sets the frame by using the [
5
] and [
6
] keys.
The internal reference signal is displayed at the upper-right corne
r