7 GENLOCK SIGNAL SETTINGS (GL SETTING)
The GL SETTING is used to set the genlock signal. To display the GL SETTING, press the
MENU key repeatedly until GL SETTING is displayed. After the GL SETTING is displayed,
select the item to be set by using the [t] and [u] keys.
7.1 Setting Warning Screen of Unlock Frequency and Log Mode.
The GENLOCK FUNCTION is used to set the warning screen of unlock frequency and log
mode.
7.1.1 Warning Screen Display
The WARNING ON/OFF is used to select whether the warning screen displays or not if
the lock frequency to be locked exceeds ±10 ppm with respect to the internal reference
frequency.
The GENLOCK ST in the STATUS screen displays the warning screen as shown in Figure
below.
Refer to Section 5.1.1, "Displaying Status".
● Description of Setting Items
ON Displays the warning screen.
OFF Does not display the warning screen. (initial setting)
Sets the warning screen of unlock frequency and log mode.
Refer to Section 7.1, “Setting Warning Screen of Unlock
Frequency and Log Mode”.
Sets the genlock timing.
Refer to Section 7.3, “Setting GENLOCK TIMING”.
1.GL SETTING
u GENLOCK FUNCTION
1.GL SETTING
v GENLOCK MODE SET
1.GL SETTING
t GENLOCK TIMING
Sets the genlock mode.
Refer to Section 7.2, “Setting GENLOCK Mode”.
[STATUS] GENLOCK ST
WARNING! OVER+10ppm
[STATUS] GENLOCK ST
WARNING! UNDER 10ppm
The frequency exceeds 10 ppm.
The frequency is under 10 ppm.