Instruction manual

2-5
immediately before the signal is removed since
STAYinSYNC mode is provided. After the external
reference signal is recovered, the system is automatically
locked.
MANUAL (STAYinSYNC): The EXT mode is automatically selected when the
external reference signal with the same format specified
to the GENLOCK input is applied after power is turned on.
If the external reference signal is accidentally removed
during operation, the instrument continues operation
under the conditions immediately before the signal is
removed since STAYinSYNC mode is provided. The
STAYinSYNC mode will be held until the reset operation
is performed via the front panel even after the external
reference signal is recovered.
Genlock Timing
Variable Range
NTSC black burst
signal: ± 5 frames
PAL black burst
signal: ± 2 frames
HDTV tri-level sync: 1 frame (entire frame range)
Resolution
H: 0.0741 μs steps (13.5 MHz clock steps)
V: Variable in 1 line steps
F: Variable in 1 frame steps
Reference Point at the
time of the NTSC black
burst input: The phase coincident point of line 4 of the NTSC and line
1 of the HDTV
Reference Point at the
time of the PAL black
burst input: The phase coincident point of line 1 of the PAL and line 1
of the HDTV
2.3.3 Analog Sync Signal Output
Format
NTSC black burst signal: SMPTE RP154, SMPTE 170M, SMPTE 318M
PAL black burst signal: EBU N14
HDTV tri-level sync: SMPTE 274M, SMPTE 296M
Output Signal
Number of Outputs: 6 Outputs (three output systems which equip with two
connectors each)
Setting Output Format: Settable
Output Connector
Output Impedance: 75Ω
Output Connector: BNC