Ni-MH • Ni-CD Battery Program
Re-peak cycle number 1 shows on the display.
Press the START/ENTER button to make the re-peak cycle num-
ber blink and press INC. or DEC. button to find the desired number
of times to re-peak charge the battery. Press the START/ENTER
button to confirm selection.
Charging NiMH • NiCD Battery in RE-PEAK Mode
Discharging NiMH • NiCD Battery in DISCHARGE Mode
Re-peak Charge Mode (NiMH and NiCD batteries only): In re-peak charge mode, the charger can peak charge
the battery once, twice or three times in a row automatically. This is good for confirming the battery is fully
charged, and for checking how well the battery receives fast charges. A five minute cool-off delay occurs after
each re-peak charge. Press START/ENTER button more than 3 seconds to start the charging.
Set discharge current on the left and final voltage on the right.
Range of the discharge current is 0.1-5.0A; range of final voltage
is 0.1-25.2V. Press START/ENTER button for more than
3 seconds to start the program.
The screen indicates the discharging state. You can press START/
ENTER button to alter discharge current, Press START/ENTER
button again to store the value, Press BATT TYPE/STOP button
to stop discharging. The emitted sound alerts the end of dis-
charging.