Lithium Battery Program for Li-Po • Li-Po HV • Li-Fe • Li-Ion
These programs are only suitable for charging and discharging lithium batteries with a nominal voltage of
3.7V, 3,.8V, 3.3V and 3.6V per cell. These batteries need to adopt different charge technique which is termed
as constant voltage(CV) and constant current(CC) method. The charge current varies according to the battery
capacity and performance. The final voltage of charge process is also very important; it should be precisely
matched with the charge voltage of the battery. They are 4.2V for LiPo, 4.35V for LiPo HV, 3.6 V for LiFe,
and 4.1V for Lilon. The charge current and nominal voltage as for cell count set on the charge program must
always be correct for the battery to be charged.
Charging Lithium Battery in BALANCE Mode
This function is for balancing the voltage of lithium-polymer battery cells while charging. In the balance
mode, the battery needs to connect to the battery’s power lead with balance wire. In this mode, the charging
process will be different from ordinary charging mode. The internal processor of the charger will monitor the
voltages of each cell of the battery pack and control charging current which is feeding to each cell to equalize
the voltage.
Note: We recommend charging lithium batteries with a balance wire in the balance mode only.
The left side of the first line shows the type of battery you
choose. The value on the left of the second line of the charger is
current the user sets. After setting the current and voltage, press
the START/ENTER button for more than 3 seconds to start the
process.
This screen displays the number of cells you set up and the
processor detects.
R=Number of cells detected by charger.
S=Number of cells set by you at the previous screen.
If both numbers are identical you can start charging process.
If not, press BATT TYPE/ STOP button to go back to previous
screen to recheck the number of cells of the battery pack before
going ahead.
This screen shows the real-time status during charge process.
Press BATT TYPE/STOP button once to stop the charge process.