INSTRUCTION MANUAL ECLIPS 2100 DUO AC/DC ECLIPS 2240 DUO AC/DC ECLIPS 2400 DUO AC/DC ECLIPS 4400 QUAD AC/DC
Warning & Safety Notes These warnings and safety notes are particularly important. Please follow the instructions for maximum safety; otherwise the charger and the battery can be damaged or at worst it can cause a fire. Also read the chapter before you begin. • Never leave the charger unsupervised when it is connected to its power supply. If any malfunction is found, TERMINATE THE PROCESS IMMEDIATELY and refer to the operation manual.
Warning & Safety Notes Charging During charge process, a specific quantity of electrical energy is fed into the battery. The charge quantity is calculated by multiplying charge current by charge time. The maximum permissible charge current varies depending on the battery type or its performance, and can be found in the information by the battery manufacturer. Only batteries that are expressly stated to be capable of quickcharge are allowed to be charged at rates higher than the standard charge current.
Introduction ECLIPS 2100 DUO • ECLIPS 2240 DUO ECLIPS 2100 DUO AC/DC 1 2 3 3 2 1 ECLIPS 2240 DUO AC/DC Technical Specs ECLIPS 2100 D 1 2 3 3 1 2 Input Voltage AC Input Voltage DC ECLIPS 2100 DUO AC/DC • 2240 DUO AC/DC Charge Power Total • • Charge Outputs Battery Types 6 7 4 4 5 9 8 1 • Charge Output Socket 2 • Balance Socket 3 • Temperature Sensor Socket 4 • USB Socket / PC Connectivity 5 • USB Power Output 5V/1A 6 • Mains input - Voltage 100V - 230V AC 7 • Cooling Fan 8 • Cooling
LIPS 2100 DUO AC/DC e Cells er ectivity AC 100 - 240V DC 11.0 - 18.0V 100 Watt • 1x max. 100 Watt • 1x 80 Watt + 1x 20 Watt • 1x 50 Watt + 1x 50 Watt 2 Charge Outputs Ni-Cd • Ni-MH • Li-Ion • Li-Fe • Li-Po • Li-Po HV • PB Channel 1 Channel 2 100 Watt 50 Watt 10 Watt 5 Watt 1 - 6 Cells 1 - 6 Cells 3.7V - 22.2V 3.7V - 22.2V 1 - 15 Cells 1 - 15 Cells 1.2V - 18.0V 1.2V - 18.0V 1 - 10 Cells 1 - 10 Cells 2.0V - 20.0V 2.0V - 20.0V 0.1A - 10.0A 0.1A - 6.0A 0.1A - 5.0A 0.1A - 2.
Introduction ECLIPS 2400 DUO • ECLIPS 4400 QUAD ECLIPS 2400 DUO AC/DC 1 2 3 4 5 4 3 2 1 ECLIPS 4400 QUAD AC/DC 1 3 2 1 3 2 1 3 2 1 3 2 Technical Specs ECLIPS 2400 D Input Voltage AC Input Voltage DC ECLIPS 2400 DUO AC/DC • 4400 QUAD AC/DC Charge Power Total •1 •1 Charge Outputs Battery Types 8 6 7 9 1 • Charge Output Socket 2 • Balance Socket 3 • Temperature Sensor Socket 4 • USB Socket / PC Connectivity 5 • USB Power Output 5V/1A 6 • Mains input - Voltage 100V - 230V AC 7 • C
LIPS 2400 DUO AC/DC e Cells er ectivity AC 100 - 240V DC 11.0 - 18.0V 400 Watt • 1x max. 400 Watt • 1x 300 Watt + 1x 100 Watt • 1x 200 Watt + 1x 200 Watt 2 Charge Outputs Ni-Cd • Ni-MH • Li-Ion • Li-Fe • Li-Po • Li-Po HV • PB Channel 1 Channel 2 400 Watt 200 Watt 40 Watt 25 Watt 1 - 6 Cells 1 - 6 Cells 3.7V - 22.2V 3.7V - 22.2V 1 - 15 Cells 1 - 15 Cells 1.2V - 18.0V 1.2V - 18.0V 1 - 10 Cells 1 - 10 Cells 2.0V - 20.0V 2.0V - 20.0V 0.1A - 20.0A 0.1A - 12.0A 0.1A - 8.0A 0.1A - 5.
Features Optimized Operating Software The TC ECLIPS chargers features the AUTO function that set the feeding current during the process of charging or discharging. Especially for lithium batteries, it can prevent the overcharging which may lead to an explosion. It can disconnect the circuit automatically and alarm once detecting any malfunction. All the programs of this product were controlled through two way linkage and communication, to achieve the maximum safety and minimize the trouble.
Features Terminal Voltage Control (TVC) The charger allows user to change the end voltage. LiPo Battery Meter The user can check battery’s total voltage, the highest voltage, the lowest voltage and each cell’s voltage. Delta-peak Sensitivity for NiMH/NiCd Delta-peak sensitivity for NiMH/NiCd battery: The automatic charge termination program based on the principle of the Delta-peak voltage detection. When the battery’s voltage exceeds the threshold, the process will be terminated automatically.
Lithium Battery Connection Diagram The TC ECLIPS chargers come with the built in switch mode power supplies. You can connect the AC power cord directly to the main AC socket (110V or 220V AC), or you can connect an external power supply (12-18v) or 12v car battery to the DC input socket. Please Note: The charger MUST be powered before you connect a battery to the charger, failure to have the charger powered up before connecting a battery can cause charger failure if any connections are incorrect.
Battery Connection Diagram ECLIPS 2100 DUO AC/DC ECLIPS 2240 DUO AC/DC ECLIPS 2400 DUO AC/DC ECLIPS 4400 DUO AC/DC Lithium Batteries Ni-xx Batteries Optional Temperature Sensor SLA Batteries m a e T y r Facto cted e l e S 11
Program Flow Chart 12
Lithium Battery Program for Li-Po • Li-Po HV • Li-Fe • Li-Ion These programs are only suitable for charging and discharging lithium batteries with a nominal voltage of 3.7V, 3,.8V, 3.3V and 3.6V per cell. These batteries need to adopt different charge technique which is termed as constant voltage(CV) and constant current(CC) method. The charge current varies according to the battery capacity and performance.
Lithium Battery Program for Li-Po • Li-Po HV • Li-Fe • Li-Ion Charging Lithium Battery in CHARGE Mode This charging mode is for charging LiPo/LiFe/LiIon battery in normal mode. Note: We recommend charging lithium batteries with a balance lead in the balance mode only. The left side of the first line shows the type of battery you choose. The value on the left of the second line of the charger is current the user sets.
Lithium Battery Program for Li-Po • Li-Po HV • Li-Fe • Li-Ion Charging Lithium Battery in FAST CHARGE Mode This screen shows the real-time status during charge process. Press BATT TYPE/STOP button once to stop the charge process. Charging Lithium Battery in STORAGE Mode This function is for charging/discharging batteries which are not used at once. This program is designed for charging or discharging of batteries of specific original state. They are classified by types: 3.75V Lilon, 3.85V LiPo, 3.
Lithium Battery Program for Li-Po • Li-Po HV • Li-Fe • Li-Ion Discharging Lithium Battery in DISCHARGE Mode The value of discharge current on the left can not exceed 1C, and the value on the right can not be under the voltage recommended by the manufacturer to avoid over discharging. press the START/ ENTER button for more than 3 seconds to start discharging. This screen displays the number of cells you set up and the processor detects. R=Number of cells detected by charger.
PB Battery Program Charging PB Battery in CHARGE Mode Set up the charge current on the left and nominal voltage on the right. Range of current 0.1-12.0A, the voltage should match the battery being charged. Press START/ENTER button for more than 3 seconds to start charging. The screen display the real-time charging status. Press START/ENTER button again to store the parameter value you set. Press BATT TYPE/STOP button to end the program.
Ni-MH • Ni-CD Battery Program Charging NiMH • NiCD Battery in CHARGE Mode This program is for charging and discharging of NiMH/NiCD batteries associated with R/C models applications. You can press Inc. or Dec. button to change the parameter value, press START/ ENTER button to store the value. The screen displays the real-time charging status. Press BATT TYPE/STOP button to stop the process. The audible sound indicate the end of process.
Ni-MH • Ni-CD Battery Program Charging NiMH • NiCD Battery in RE-PEAK Mode Re-peak Charge Mode (NiMH and NiCD batteries only): In re-peak charge mode, the charger can peak charge the battery once, twice or three times in a row automatically. This is good for confirming the battery is fully charged, and for checking how well the battery receives fast charges. A five minute cool-off delay occurs after each re-peak charge. Press START/ENTER button more than 3 seconds to start the charging.
Ni-MH • Ni-CD Battery Program Charging NiMH • NiCD Battery in CYCLE Mode You can set up sequence on the left and the number of cycles on the right. Range of the cycle number is 1-5. Press BATT TYPE/STOP button to stop program, you can press Inc. or Dec. button to alter charge current, the sound indicates the end of program. Lithium Battery Meter Program The user can check battery’s total voltage, the highest voltage, the lowest voltage and each cell’s voltage.
Battery Memory Set Program The example is Lipo battery pack (2S/7.4V). For your convenience, the TC ECLIPS charger have a data storage and load program, it can store 10 different battery data represent the respective specifications of batteries, you can call back the data when charging/discharging without setting up the program again, press START/ ENTER button to make it blink and use INC. or DEC. to set up the parameter.
System Set-Up It will be operated with the default value of the essential user settings when it is connected to a DC 11~18V battery at the first time. The screen displays the below information in sequence and the user can change the value of parameter on each screen. Press START/ ENTER button to make it blink then change the value by press Dec. or Inc. button. The value will be stored by press START/ENTER button again. User set up starting screen. User set up starting screen.
System Set-Up This program sets the maximum charge capacity that will be supplied to the battery during charge. If the deltapack voltage is not detected nor the safety time expired by any reason, this feature will automatically stop the process at the selected capacity value. The beep sounds at every time pressing the buttons to confirm your action. The beep or melody sounded at various times during operation to alert different mode changes. These audible sounds can be on or off.
Informations During The Process You can inquire various information on LCD screen during charging or discharging process. When you press Dec. button, the screen will display the user’s settings. And also you can monitor the voltage of individual cell by press Inc. button when the individual connection cable is linked to the Lithium battery being processed. It comes to the final voltage when the program ended. Present input voltage. This screen shows the external and internal temperature.
Warning & Error Messages It incorporates a variety of functions for the systems to verify processes and the state of the electronics. In case of an error the screen will display the cause of error and emit an audible sound. Incorrect polarity connected. The battery is interrupted. The Battery connection is wrong. The balance connect is wrong. Input voltage less than 11V. Input voltage higher than 18V. Voltage of one cell in the battery pack is too low. Voltage of one cell in the battery pack is too high.
Warranty Conditions & Liability Disclaimer If material defects or manufacturing faults should arise in a product distributed or manufactured by Team Corally, a division of JSP Group Intl BVBA, and purchased by a consumer, we Team Corally acknowledge the obligation to correct those faults or defects within the limitations described below. This manufacturers warranty is in addition to, and does not affect, the legal or contractual rights of the consumer which arise from the purchase of such products.
Warranty Conditions & Liability Disclaimer Duration of Validity The claim period is 24 months from the date of purchase of the product by the consumer from a dealer in the European Community (EC) counted from the date of purchase. The claim period is 12 months from the date of purchase of the product by the consumer from a dealer outside the European Community (EC) counted from the date of purchase.
Documents Declaration of Conformity Team Corally ECLIPS 2100 DUO AC/DC Team Corally, a division of JSP Group Intl BVBA declares under sole responsibility that the battery charger ECLIPS 2100 DUO AC/DC with reference nr C-48489 to which this declaration relate, conforms with the following LVD standards; EN 60335-1:2012 +A11:2014 EN 60335-2-29:2004 +A2:2010 The battery charger ECLIPS 2100 DUO AC/DC with reference nr C-48489 also conforms with the following EMC standards; EN 55014-1:2006 +A1:2009 +A2:2011 EN
Documents Declaration of Conformity Team Corally ECLIPS 2240 DUO AC/DC Team Corally, a division of JSP Group Intl BVBA declares under sole responsibility that the battery charger ECLIPS 2240 DUO AC/DC with reference nr C-48490 to which this declaration relate, conforms with the following LVD standards; EN 60335-1:2012 +A11:2014 EN 60335-2-29:2004 +A2:2010 The battery charger ECLIPS 2240 DUO AC/DC with reference nr C-48490 also conforms with the following EMC standards; EN 55014-1:2006 +A1:2009 +A2:2011 EN
Documents Declaration of Conformity Team Corally ECLIPS 2400 DUO AC/DC Team Corally, a division of JSP Group Intl BVBA declares under sole responsibility that the battery charger ECLIPS 2400 DUO AC/DC with reference nr C-48491 to which this declaration relate, conforms with the following LVD standards; EN 60335-1:2012 +A11:2014 EN 60335-2-29:2004 +A2:2010 The battery charger ECLIPS 2400 DUO AC/DC with reference nr C-48491 also conforms with the following EMC standards; EN 55014-1:2006 +A1:2009 +A2:2011 EN
Documents Declaration of Conformity Team Corally ECLIPS 4400 QUAD AC/DC Team Corally, a division of JSP Group Intl BVBA declares under sole responsibility that the battery charger ECLIPS 4400 QUAD AC/DC with reference nr C-48493 to which this declaration relate, conforms with the following LVD standards; EN 60335-1:2012 +A11:2014 EN 60335-2-29:2004 +A2:2010 The battery charger ECLIPS 4400 QUAD AC/DC with reference nr C-48493 also conforms with the following EMC standards; EN 55014-1:2006 +A1:2009 +A2:2011
Team Corally • Geelseweg 80 • 2250 Olen • Belgium Tel: +32 14 25 92 94 • info@corally.