Specifications

81
Cleaning - The buttons Print KY Test and Print CM Test will print some test patterns which shows
the quality of the print heads.
If some lines are missing in the print out, the corresponding nozzle in the print head has a prob-
lem. But the print head is still OK, when only a few nozzles have a problem. Only if there are more
nozzles missing, you will see it in the print out as missing lines.
Normally it is possible to reactivate a problematic print head with the cleaning functions below.
Pressing the Clean buttons will clean the print heads.
You have to start with Clean lightto enable
the other cleaning functions. This is to avoid damaging the print heads while cleaning.
With the button Print Testfileyou can start the print of a test image to check the result. We recom-
mend to print this file once after a cleaning process.
Printed test for the head KY (blacK , Yellow) Printed test for the head CM (Cyan, Magenta)
Alignment - This button will start the print head alignment process.
Note: When you start the alignment process, you have to finish it after a certain point. Otherwise the actual values
will be overwritten without proper new values. Therefore the first dialog after starting the alignment gives you
the chance to quit the alignment process before the actual values are overwritten.
Prepare two printable CD, one insert into the printer and click to the Alignment button. Next click to 20ips button and
next click to CD1 button. When printer stops exchange the CD in the printer and click to CD2 button. Remove the
second CD from the tray.
Quality print option Run print alignment
Printer