User guide

CME 2 User Guide Digital Inputs and Outputs
Copley Controls 61
6.2.3: Custom Digital Output Settings: Custom Event
Any of the amplifier’s digital outputs can be programmed to respond to a combination of
events including faults, warnings, and status indications. The output goes active when one
or more of the selected events take place.
Configure a Custom Event output
1
Choose Custom Event for an output and then click Configure Custom to open the
Event Configuration screen.
2
Select one or more Custom Event Functions (p. 62).
Multiple functions are OR’ed together, so any event activates the output.
3
Choose Output Active Hi/Off or Output Active Lo/On.
4
To latch the output, set the Latch Output option.
The Clear button clears all check marks.
!
DANGER
Latching an output does not eliminate the risk of unexpected motion with
non-latched faults.
Associating a fault with a latched, custom-configured output does not latch the
fault itself. After the cause of a non-latched fault is corrected, the amplifier re-
enables without operator intervention. In this case, motion may re-start
unexpectedly.
Failure to heed this warning can cause equipment damage, injury, or death.
5
Click OK to save changes to amplifier RAM and close the screen.