User guide

Motor/Feedback CME 2 User Guide
48 Copley Controls
Absolute A
In the Bits text field specify the number of bits used for single turn resolution (see encoder
data sheet). In the Number of Revolutions text field specify the number of turns (see
encoder data sheet). Optionally, enter a number of counts per rev bits to ingnore in the
specified box. Choose bit rate.
!
WARNING
When a battery error exists, absolute position may not be true (whether
the Ignore Battery Error option has been checked or not).
FAILURE TO HEED THIS WARNING CAN CAUSE EQUIPMENT
DAMAGE, INJURY, OR DEATH.
Tamagawa
Absolute A
and
Panasonic
Absolute A
Format
In the Bits text field specify the number of bits used for single turn resolution (see encoder
data sheet). In the Number of Revolutions text field specify the number of turns (see
encoder data sheet). Optionally, enter a number of counts per rev bits to ignore in the
specified box. The bit rate defaults to 2.5 MB/s. Zero encoder in the specified box when
needed.