CME 2 User Guide Amplifier Setup Procedure
Copley Controls 31
...Setup Procedure, continued:
7
Configure faults
Click Configure Faults to open the Fault Configuration screen and set latching faults as
needed. See Faults (p. 87).
Click OK to close the Fault Configuration screen.
8
Configure an optional regen resistor
If the amplifier is equipped with a regen resistor, click Regen Settings to open the Regen
Settings screen. See Regen Resistor Configuration (p. 213) for regen resistor
parameters.
Click OK to close the Regen Settings screen.
9
Phase and jog the motor
Apply AC or HV power.
Phase Motor with Auto Phase (p. 94).
To verify Auto Phase results, Phase Motor Manually (p. 104).
Run a move in jog mode (p. 151) to verify that the amplifier can drive the motor.
10
Tune the control loops
Starting with the Current Loop set up and tune all applicable Control Loops (p. 111).
If you are setting up a linear motor, you can optionally
Tune All Loops with Auto Tune (Linear Motors) (p. 133) instead.
11
Set gains and limits for stepper mode (stepper only)
If tuning a stepper amplifier in stepper mode:
Set Position Limits in Stepper Mode (p. 140).
If using Encoder Correction, Set Encoder Correction Gain (p. 142).
Tune Stepper Detent Gain (p. 143).
12
Configure Homing
Configure Homing (p. 145).
Continued…