User guide

Gain Scheduling CME 2 User Guide
224 Copley Controls
Create a Gain Scheduling Table, continued:
4
If there is already a table stored in flash:
Optionally Save Settings and Table Data to Disk (p. 226).
Then click the Delete tool to delete the gain scheduling table data from
amplifier flash and PC RAM.
5
On the Table tab, click the Create a new gain scheduling table tool. See the
prompt:
6
Enter the number of lines (the number of gain adjustment specifications).
Click OK.
7
Enter the Key Parameter and gain adjustment values. All values must be integer, and
each Key Parameter value must be greater than the previous as described in Gain
Scheduling Table Guidelines (p. 227). Click in a field to enter or modify a value.
Standard mouse and keyboard editing techniques are available.
8
On the Table tab, click Save gain scheduling table and setup to amplifier
flash memory before attempting to run the new table. This saves the Table tab
data and all Config tab settings.
9
Close the screen.