User guide

CME 2 User Guide Homing Methods
Copley Controls 211
E.3.14: Upper Home Outside Index
Direction of Motion: Positive
Home is the first index pulse on the positive side of the positive edge of a momentary
home switch. Initial direction of motion is positive. If the initial motion leads away from the
home switch, the axis reverses on encountering the positive limit switch; then, if a
negative limit switch is activated before the home switch, an error is generated.
Home Switch
Index Pulse
H
H
Positive Limit
Switch
Direction of Motion: Negative
Home is the first index pulse on the positive side of the positive edge of a momentary
home switch. Initial direction of motion is negative if the home switch is inactive. If the
initial position is right of the home position, the axis reverses on encountering the home
switch.
Home Switch
Index Pulse
Negative Limit
Switch
H
H