User guide

Control Panel CME 2 User Guide
150 Copley Controls
14.4: Control Functions
The Control area of the screen provides functions related to overall amplifier control. The
screen options vary with model and configuration.
Use the Control Panel Control Functions
Control the operational state of the amplifier using the buttons as described
below.
Control
Description
Enable
Click to software enable the amplifier.
Disable
Click to software disable the amplifier. This will also stop any CVM
programs that are running.
Set Zero Position
Click to set the amplifier’s actual position counter to zero.
Clear Faults
Click to clear all amplifier faults.
Reset
Click to reset the amplifier.
!
WARNING
Risk of unexpected or uncontrolled motion.
Using the CME 2 Set Zero Position function while the amplifier is operating under
external control could cause unexpected or uncontrolled motion.
Failure to heed this warning can cause equipment damage.