User guide

Xenus Plus User Guide Specifications
Copley Controls 63
3.8: Digital Inputs
XEL/XPL/XML
Channels
15 (IN1~IN15)
IN1~IN2, IN15
IN3~IN6
IN7~IN14
Type
Schmitt trigger w/ RC filter,
24Vdc max
Non-isolated line receiver w/
RC filter, programmable as 4
single-ended or 2 differential
Single-ended
Opto-isolated, bi-polar, 2
groups of 4 with common for
each group
Input Voltage
Range
0 Vdc-24 Vdc
0-12Vdc
±15 - 30 Vdc
Logic Low Input
Voltage
<= +1.13 Vdc
<= +2.3 Vdc
N/A
Logic High Input
Voltage
>= +3.15 Vdc
>= +2.7 Vdc
N/A
Scan Time
250 s
250 s
250 s
Debounce
Type
Time
Digital
Programmable 0 - 10,000 ms
Digital
Programmable 0 - 10,000 ms
Digital
Programmable 0 - 10,000 ms
Function
IN1 enable
IN2~IN15 programmable
Note: Inputs 3&4 and 5&6 can be programmed to function as differential pairs as digital command
inputs.
XE2/XP2/800-1782/800-1808
Channels
22 (IN1~IN22)
IN1,11,21~22
IN2~5,12-15
IN6~9,16~19
IN10,20
Type
Schmitt trigger w/ RC
filter, 24Vdc max
Non-isolated line
receiver w/ RC filter,
programmable as 4
single-ended or 2
differential Single-
ended
Opto-isolated, bi-
polar, 2 groups of 4
with common for each
group
Motor overtemp
signals on feedback
connectors
Input Voltage
Range
0 Vdc-24 Vdc
0-12Vdc
±15 - 30 Vdc
0 Vdc-24 Vdc
Logic Low Input
Voltage
<= +1.13 Vdc
<= +2.3 Vdc
<= +6 Vdc
<= +1.13 Vdc
Logic High Input
Voltage
>= +3.15 Vdc
>= +2.7 Vdc
>= +10 Vdc
>= +3.15 Vdc
Scan Time
250 s
Debounce
Type
Time
Digital
Programmable 0 -
10,000 ms
Digital
Programmable 0 -
10,000 ms
Digital
Programmable 0 -
10,000 ms
Digital
Programmable 0 -
10,000 ms
Function
All programmable
Note: 800-1782 does not utilize IN21-22 and dedicates IN16-19 to optical limit switches of motors.