User guide

Xenus Plus User Guide Specifications
Copley Controls 59
3.1: Agency Approvals
CE Compliant
UL Compliant
RoHS Compliant
Standard
XEL/XPL/XML
XE2/XP2/800-1782/800-1808
UL
UL 61010-1 Compliant
UL 61800-5-1 Compliant
Functional Safety
IEC 61508-1, IEC 61508-2
ISO 13849-1
ISO 13849-2
IEC 61800-5-2
Electrical safety
IEC 61010-1
UL 61010-1
IEC 61800-5-1
UL 61800-5-1
EMC
IEC 55011:2009 /A1:2010, CL A
IEC 61000-6-1:2007
SEMI F47-0706
IEC 61800-3:2004+A1:2011*
SEMI F47-0706
* The Xenus Plus Dual Axis models comply with the requirements for immunity to low frequency disturbances
specified in IEC 61800-3:2004+A1:2011
*CE Declaration of Conformity available at
http://www.copleycontrols.com/Motion/Downloads/xenusData.html
3.2: Power Input
Model
XEL-230-18 (-R)
XPL-230-18 (-R)
XML-230-18 (-R)
XEL-230-36 (-R)
XPL-230-36 (-R)
XML-230-36 (-R)
XEL-230-40 (-R)
XPL-230-40 (-R)
XML-230-40 (-R)
XE2-230-20 (-R)
XP2-230-20 (-R)
800-1808
800-1782
Mains Voltage
100 - 240 Vac
1 Ø or 3 Ø
Mains Frequency
47 to 63 Hz
Max Mains Current, 1Ø*
10.1 Arms
20.0 Arms
20.0 Arms
20.0 Arms
Max Mains Current, 3Ø*
6.4 Arms
10.4 Arms
15.4 Arms
15.4 Arms
Current Inrush
15 A peak at 120 Vac
35 A peak at 240 Vac
Logic Supply Voltage
+20 to +32 Vdc
Logic Supply Current
500 mA maximum
1.1 A maximum**
*The actual mains current is dependent on the mains voltage, number of phases, and motor load and operating
conditions. The Maximum Mains Currents shown above occur when the drive is operating from the maximum input
voltage and is producing the rated continuous output current at the maximum output voltage.
**Logic supply current draw depends on the number of encoders connected to the drive. The maximum current draw
given assumes that the four drive encoder supplies (+5V) are each loaded to 500mA.