User guide

Xenus Plus User Guide Operational Theory
Copley Controls 40
2.10.5: XML J6: Drive and MACRO Network Status Indicators
XML J6 STAT Indicator: Drive Status
Indicator color/blink codes are described below.
Color/Blink Code
Meaning
Not illuminated
No +24 Vdc power to drive.
Steady green
Drive is enabled and operational.
Slow-blinking green
Drive is disabled. No faults or warnings are active.
Fast-blinking green
A limit switch is active. The drive is enabled.
Green flash twice
followed by a pause
STO is active, One or both STO inputs are de-energized. The drive is hardware & software
enabled but the PWM outputs cannot produce current in the motor when STO is active.
Steady red
A non-latched fault has occurred.
Blinking red
A latched fault has occurred.
XML J6 NET Indicator: MACRO Network Status
NET
Description
Off
MACRO network has not been detected.
Blinking green
MACRO network detected and has disabled drive.
Green
MACRO network detected and is trying to enable drive. This condition can occur while the
AMP LED shows any of its valid color combinations.
Steady red
MACRO network errors have been detected.
STAT-Drive Status
NET-MACRO Network Status
J6