User guide
Xenus Plus User Guide Ordering Guide and Accessories
Copley Controls 156
F.7: Copley Standard Regen Resistor Specifications
F.7.1: Specifications
Specifications for Copley’s standard regen resistors are described below.
Model
Resistance
Default
Continuous
Power
Max
Continuous
Power
Peak
Power
Peak
Power
Time
For Use With
XTL-RA-03
30 Ohms
65 W
400 W
5 kW
1000 ms
XEL/XML/XPL-230-18
XEL/XML/XPL-230-18-R
XTL-RA-04
15 Ohms
65 W
400 W
10 kW
1000 ms
XEL/XML/XPL-230-36
XEL/XML/XPL-230-36-R
XEL/XML/XPL-230-40
XEL/XML/XPL-230-40-R
XE2/XP2-230-20/800-
1782/800-1808
XE2/XP2-230-20-R
WARNING
High Temperature Risk.
Setting Default Continuous Power for a standard Copley regen resistor to a value greater
than the default of 65 W may cause the resistor casing to heat to temperatures that could
cause injury. If higher settings are required, contact Copley Controls customer support.
Failure to heed this warning can cause equipment damage or injury.
F.7.2: Dimensions
The diagram below shows XTL-RA-03 and XTL-RA-04 mounting dimensions (in mm).
!