User guide
Wiring Xenus XTL User Guide
54 Copley Controls Corp.
4.7: CAN Bus (J6)
Mating Connector
8-position, modular connector (RJ-45 style). Copley Controls provides the following assemblies:
• Prefabricated 10 foot cable, PN XTL-NC-10
• Prefabricated 1 foot cable, PN XTL-NC-01
• Terminator Plug, PN XTL-NT
A diagram of the female connector is shown below.
12345678
Pin Description*
Pin Signal Function
1 CAN_H CAN_H bus line (dominant high)
2 CAN _L CAN_L bus line (dominant low)
3 CAN_Gnd Ground / 0 V / V-
4 -- No connection
5 -- Pass though to second connector, no internal connection
6 CAN_SHLD Pass though to second connector, no internal connection
7 CAN_Gnd Ground / 0 V / V-
8 CAN V+ Pass through to second connector, no internal connection
*Table applies to both CAN connectors
CAN Bus Wiring Diagram
Amplifier J6
CAN +
CAN
-
CAN Gnd
CAN +
CAN
-
CAN Gnd
Note 1: If this is the last amplifier on the network,
use Copley Terminator Plug PN STP-NT
to terminate the bus.
CAN Network
CAN Network
J6-1
J6-2
J6-4
J6-3
J6-5
J6-6
J6-7
J6-8
J6-1
J6-2
J6-4
J6-3
J6-5
J6-6
J6-7
J6-8
Opto-isolation