User guide

Using CME 2 Xenus XTL User Guide
126 Copley Controls Corp.
6.2.3: Data Management Tools
Amplifier Data Management Tools
Operations performed using the amplifier data management tools at the top of the Main screen
(shown below) affect amplifier settings, including motor/feedback data. (CVM Control Program
data is not saved by these operations.)
Amplifier Data Management Tools
The amplifier data management tools are described below.
Icon Name Description
Save amplifier
data to disk
Saves save all user-entered data represented on all screens from volatile and flash
memory to a disk file with a .ccx filename extension.
Restore
amplifier data
from disk
Restores amplifier and motor data from a .ccx file to the amplifier’s volatile and flash
memory. Note that only certain data is saved to flash by this operation (the data described
as Flash only on p. 125). To assure that all data (including the data described as
Flash and Volatile) is stored in flash, use the Save amplifier data to flash tool.
Save amplifier
data to flash
Saves contents of the amplifier’s volatile memory to the amplifier’s flash memory.
Restore
amplifier data
from flash
Restores contents the amplifier’s flash memory to amplifier’s volatile RAM.
To use a data management tool, click the icon and respond to prompts.
Motor Data Management Tools
Operations performed using the data management tools at the bottom of the Motor/Feedback
screen (shown below) affect only user-entered data that is represented on the Motor/Feedback
screen.
Motor/Feedback
Data Management Tools
The motor data management tools are described below.
Icon Name Description
Save motor
data to disk
Saves only motor/feedback data from the PC to a disk file with a .ccm filename extension.
Amplifier data that is not represented on the Motor/Feedback screen is not saved in this
file, and this operation does not affect any .ccx files.
Restore motor
data from disk
Restores only motor data from a disk file with a .ccm filename extension to the PC.
Amplifier data that is not represented on the Motor/Feedback screen is not affected.
Save motor
data to flash
Saves the contents of the Motor/Feedback screen from PC to the amplifier’s flash memory.
Amplifier data that is not represented on the Motor/Feedback screen is not saved. Can be
used to assure that all changes are saved to flash without closing the Motor/Feedback
screen.
Restore motor
data from
flash
Restores only motor data from the amplifier’s flash memory to the PC. Amplifier data that is
not represented on the Motor/Feedback screen is not affected. Can be used before closing
the Motor/Data screen to restore settings to the previously saved values.
To use a data management tool, click the icon and respond to prompts.