User guide
ServoTube 25/38 Module User Guide
Chapter 3
Maintenance
Page 24
Ret and tighten the cable retaining clamp.•
Screw on and tighten the pressure nut.•
Replace the pod cover taking care not to damage the sealing gasket on the pod.•
Fit the M3 xings according to the record made when they were removed, and tighten to a torque of 0.7 Nm.•
Place the cables back inside the drag chain.•
Fit new cable ties to secure the cables as originally tted. •
Re-clip the covers that were previously unclipped.•
BELLOWS REPLACEMENT
Removal
Remove the two M6 button head xings securing the bellows system end plate to the backing bar, Figure 3.8.•
Figure 3.8
Move the forcer towards the side being replaced and slide the bellows with attached system end plate, out of •
the module backing bar.
Fold the bellows (not shown) still connected to the system end plate, back over the top of the forcer body to •
give access to the xings that secure the bellows xing plate to the forcer, see Figure 3.9.
Remove the four M3 countersunk xings that secure the bellows xing plate to the forcer and remove the •
bellows from the module assembly. The module with bellows removed is shown in Figure 3.10.
Backing bar
System endplate
Remove these screws
Bellows
fixing
plate
M3 CSK
fixings (4 off)
Forcer
Figure 3.9 Figure 3.10