ADDITIONAL ENCODER
If an additional encoder has been specied there will be a third cable that should be connected to the relevant
encoder input on the drive amplier used. When used with the Copley Xenus (XTL-S) or Xenus (XSJ-S) an adaptor
cable is supplied.
Connections are available via a 9-way D-sub male connector.
FUNCTION +5Vd.c. 0V A+ A- B+ B- Z+ Z- Screen
PIN NUMBER 5 1 2 6 4 8 3 7 Case
LIMIT SWITCHES
WARNING. These limit switches are not intended as safety devices or as part of a system
intended to ensure personal safety. When two switches are mounted in close proximity (as
in the case of a left and right limit switch), a minimum of 30mm spacing between sense areas
must be maintained.
If limit switches have been specied there will be an additional cable per limit switch. These should be connected
to the relevent I/O on the drive amplier.
The output for all types can be normally closed (NC) or normally open (NO) open collector transistor. The NC
ouptuts switch open when a limit is detected and current stops owing in the LOAD. The NO ouputs switch closed
when a limit is detected and current starts owing in the LOAD.
A red indicator shows when a limit is detected.
OVER-TEMPERATURE SENSOR
CAUTION. It is strongly recommended that the forcer over-temperature sensor is connected
to the drive amplier or servo controller at all times in order to reduce the risk of damage to
the forcer due to excessive temperatures.
Black (LOAD)
Blue (0V)
NPN
LOAD
Brown (+V)
Black (LOAD)
Blue (0V)
PNP
LOAD
Brown (+V)