User guide
ServoTube 25/38 Module User Guide
Page 13
Chapter 2
Installation
DRAG CHAIN
FOR CABLE ROUTING
(LARGER SIZE OPTIONAL)
FORCER
BELLOWS
SYSTEM END PLATE
SYSTEM CLAMPS
(MOUNTED NOT MORE
THAN 150mm APART)
EACH SIDE, IF REQUIRED
FORCER LENGTH
LENGTH
A
A
CUSTOMER ADJUSTABLE LIMIT
SWITCHES (OPTIONAL)
FACTORY SET FOR 5.0mm FROM
END OF STROKE
FOR LARGER
DRAG CHAIN
(ORDER REF. I3)
68
94
65
38.5
86
18.5
62
17
21
50
102
(CLAMP BOLT CENTRES)
78
C
B
SECTION A-A
1
LINEAR ENCODER
(OPTIONAL)
DATUM ACTUATION AT
20mm FROM END OFSTROKE
2.5
8.2
5.2
4.8
DETAIL C
4.5
6.2
10.5
9.0
DETAIL B
2
3
CABLES:
Ø7.6 POWER CABLE
1.
Ø5.8 SENSOR CABLE
2.
Ø4.5 ENCODER CABLE (OPTIONAL)
3.
SLOTS FOR M5 T-NUTS &
M6 SQUARE / HEX. NUTS
SLOTS FOR M4 SQUARE NUTS
SB25 OUTLINE DRAWING
2504 2506 2508 2510
Length Stroke Length Stroke Length Stroke Length Stroke
271 21 - - - - - -
297 47 - - - - - -
322 72 322 21 - - - -
348 98 348 47 - - - -
374 124 374 73 374 22 - -
411 149 399 98 399 47 - -
452 175 425 124 425 73 425 22
491 200 462 149 450 98 450 47
531 226 503 175 476 124 476 73
572 252 543 201 515 150 502 99
611 277 582 226 554 175 527 124
651 303 623 252 594 201 566 150
690 328 662 277 633 226 605 175
730 354 702 303 674 252 645 201
771 380 742 329 714 278 686 227
810 405 781 354 753 303 725 252
850 431 822 380 793 329 765 278
2504 2506 2508 2510
Length Stroke Length Stroke Length Stroke Length Stroke
889 456 861 405 832 354 804 303
929 482 901 431 873 380 844 329
970 508 941 457 913 406 885 355
1009 533 980 482 952 431 924 380
1049 559 1021 508 992 457 964 406
1088 584 1060 533 1031 482 1003 431
1169 636 1140 585 1112 534 1084 483
1248 687 1220 636 1191 585 1163 534
1327 738 1299 687 1271 636 1242 585
1406 789 1378 738 1350 687 1322 636
1486 840 1457 789 1429 738 1401 687
1567 892 1538 841 1510 790 1482 739
1646 943 1618 892 1589 841 1561 790
1725 994 1697 943 1669 892 1640 841
1804 1045 1776 994 1748 943 1720 892
1884 1096 1855 1045 1827 994 1799 943
1964 1148 1936 1097 1908 1046 1880 995
SB25 STROKE TABLE
Approximate module mass (kg)
2504 2506 2508 2510
(0.00885 x L)+2.49 (0.00885 x L)+2.94 (0.00885 x L)+3.49 (0.00885 x L)+3.85
where L = Length in mm