SDS

Product name: COPIC INK
Prepared on: February 18, 2020
Revised on: April 21, 2020
7 / 14
3202112070116
:
Use containers designated by the Fire Service Act and the U.N.
transportation regulations for storage.
The container should be labeled with a GHS label.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Allowable exposure limit
:
Isopropyl alcohol: 200 ppm
:
Isopropyl alcohol: 400 ppm (980 mg/m
3
)
:
Ethyl alcohol: STEL 1000 ppm
Isopropyl alcohol: TWA 200 ppm, STEL 400 ppm
1-Propanol (n-Propyl alcohol): TWA 100 ppm
:
As this product contains the substance subjected a risk assessment under
the Industrial Safety and Health Act, the risk assessment shall be
conducted. Based on the risk assessment conducted, necessary measures
shall be taken to remove health hazard to workers.
This product contains Isopropyl alcohol as a second-class organic solvent
under Ordinance on Prevention of Organic Solvent Poisoning.
Therefore, pursuant to the ordinance, in a working place with poor
ventilation, wholly enclose the emission source of organic solvent
vapour, or install a local exhaust ventilation or push-pull type ventilation
at the emission source, or install a general ventilation system.
Although the above necessary facility measures are taken, if there may
be a remaining risk to expose over the exposure limits, wear a respiratory
protection mask.
Use explosion-proof electrical/ventilating/lighting equipment.
Take precautionary measures against static discharge.
Install face-washing facility and safety shower in the working place for
storing and handling this product.
When vapour, fume, and mist are generated in the process, install an
exhaust ventilation to keep airborne pollutants below the Administrative
control levels and/or Allowable exposure limits.
:
Wear an air-supplied mask or gas mask for organic gases.
Wear personal respiratory protection if necessary.
When the Ordinance on Prevention of Organic Solvent Poisoning
requires, or there is a risk that an exposure of vapour exceeding to
occupational exposure limits occurs, or if necessary, wear an air-supplied
mask or a national certificated gas mask for organic gases.
For a proper use, or maintenance, follow the related regulations, or user's
manual of the manufacturers.
:
Wear protective gloves.
When wearing protective gloves, check the specification, such as a
breakage time, announced by the glove manufacturer.
Check the condition of the glove during use. Replace the gloves if it is
damaged or torn.
:
Use eye protection.
Wear protective goggles for chemical droplet and/or an appropriate
protective face mask. Wear safety eyeglasses.
If there is a risk of eye or facial exposure to splash or spray, wear