User’s manual for DVR *This manual is tailored for MPEG4-100FPS/120FPS 9-channel and 16-channel digital video recorder *This manual takes 16-channel digital video recorder as example 1
Before operation, we strongly advise you to read the user manual and keep it properly for later using. This manual is an operation guide but not quality warranty. We may reserve the rights of amending the typographical errors, inconsistencies with the latest version, software upgrades and product improvements, interpretation and modification. These changes will be published in the latest version without special notification.
Table of Contents Digital Video Recorder (DVR) Introduction ..................................................................................................... 6 1.1 Product introduction .......................................................................................................................... 6 1.2 Features of this DVR ......................................................................................................................... 6 Installation Notice .............................
3.2.1 SETUP-SYSTEM .................................................................................................................. 35 3.2.2 SETUP-LIVE ......................................................................................................................... 40 3.2.3 SETUP-REC ......................................................................................................................... 43 3.2.4 SETUP-STORAGE ........................................................................
Appendix C The meaning of some abbreviation .................................................................................
Digital Video Recorder (DVR) Introduction 1.1 Product introduction This DVR is designed specially for CCTV system. It adopts embedded processor and embedded operating system working with the high-powered code and decode chip.
Various recording resolutions, D1,Half D1 and CIF Support channel security by hiding live display Display the local record state and the basic information Remote controller equipped Support two level password control: administrator and common user Operation log recording and searching Video system (PAL or NTSC) can be detected automatically and selected manually Recording list can be deleted one by one or by all and locked to protect the important records Support water mark technology Format Standard MPEG-
Support HDD recycle Up to 16CH playback, fast forward(2X,4X,8X,16,32X,64X and 128X)and slow forward modes; play the record frame by frame; jog shuffle to forward/backward function, which is including frame rate adjusting Support remote playback in “Net Client” through LAN or internet Three record search mode: time search, event search, file search Alarm 9/16 alarm inputs and 4 alarm outputs, TTL alarm output PTZ control Support decoder which communicates with RS485 Support speed dome Support PTZ through n
Support IE browser, for remote view (automatically download active-x ) 9
Installation Notice Attention: Before connecting to the other equipments, please make sure that the device is powered off. Do not hot plug in! 2.1 Check the accessories in the carton Check accessories when you receive the machine, to make sure you have all the parts. Normally it shall contain: a remote controller, a power cable, a CD-Rom with “Net Client” software, screws for installing HDD 2.2 Install the HDD 2.2.
2.2.2 Install tool One cross-screwdriver 2.2.3 Install process ⑴ Open the DVR by screwdriver ⑵ Set one as master and the other as slave if two HDDs are connected to one ATA interface!!! Attention: Same HDD connected to parallel cable can not be set as master+master or slave+slave, must be master+slave!!! HDD setup: Take the HDD of Maxtor (DiamondMax Plus 8 ATA/133 40GB) as example.
Jump line area The picture blow is the connection section of the HDD. Jump line area Jump line according to the cutline above MASTER SLAVE The sequence of read/write data from HDD The ATA interface which is near the motherboard center is the secondary interface, the next ATA interface which is near the motherboard fringe is the primary interface. The sketch is in the following. The HDD names that are shown in the DVR system are HDD A/B/C/D.
primary ATA interface is HDD A, the slave is HDD B. The master HDD connected to secondary ATA interface is HDD C, the slave is HDD D. The record sequence: HDD A→HDD B→HDD C→HDD D Overwrite sequence: The sequence is irrespective with HDD. The DVR over write HDD from the oldest record file when HDD is full. Motherboard ⑶ Operation ① Put the HDD into the HDD fixation rack. If the user wants to install more than two HDD, please install the HDD into the rack below first.
19 pins are in the other row). Make sure pins are plugged into interface exactly. ④ Connect the power supply to HDD Sketch map of installation Close the device cover and lock it by screws Attention: ⒈ Please format the HDD before you using. ⒉ If the user wants to connect the CD/DVD driver to the ATA interface, please choose the secondary interface, that is near the center of the motherboard.
1 2 First, put the HDD into the HDD fixation rack Second, fix the HDD by two screws on both sides 4 3 Third, connect the HDD cable Fourth, connect the power supply to HDD Sketch map of installation 15
2.3 Back panel and interface terminals Attention: The interfaces on the back panel please refer to the real object, there might be slightly difference from below sketch. 2.3.
1 Video input 1-16 2 Spot output 3 Video output 4 S video output 5 Audio output 17
6 LAN port 7 Audio in 1-4 8 Alarm input1-16 9 Alarm output
10 Fan vent 11 Power plug 12 USB port 13 VGA port 14 RS 232 port(Null) 15 RS485 port 19
2.3.2 Back panel of 9-channel DVR CAM1 CAM3 CAM2 SPOT OUT CAM4 VIDEO OUT AUDIO IN 1 AUDIO IN 2 CAM9 CAM7 CAM5 CAM6 S VIDEO CAM8 ALARM IN 1 2 3 4 5 6 7 8 9 ALARM OUT 1 2 3 4 AUDIO IN 3 AUDIO IN 4 AUDIO OUT COM + - GND RS-485 LAN USB VGA Back panel of 9-channel DVR The difference between 9-channel and 16-channel is as following: Video input: The video input channel of 9-channel is nine. Alarm input: The alarm input channel of 16-channel is sixteen.
2.4 Front panel and interface terminals Attention: The buttons on the front panel please refer to the entity, there might be slightly difference from below sketch.
7 Zoom/Focus control 8 Audio on/off button 9 Backup button 10 Menu button 11 Function button 12 Status button 13 Leftward 14 Upward 15 Enter button 16 Rightward 17 Downward 18 Record button 19 Shuttle: to control the DVR to play the record frame by frame.
Fast Reverse 24 Fast forward 25 Stop 26 Remote receiver 27 USB port 28 LED indicator lights, for power, HDD and backup, network status, playback status and record status respectively. controller Attention: The CD-RW/DVD-RW is optional, depending on the user. If the user connects CD-RW/DVD-RW to the ATA interface, the max number of HDD that connects to the ATA interface is three.
2.5 Remote controller description Put the Battery into the Remote controller: Open the battery cover of Remote controller Put in two AAA batteries and make sure that they are not inserted upside down. Put back the battery cover The entire view of remoter controller The buttons description: Number 1 24 Icon Description Record button: Press this button to start recording if the DVR does not record. Press this button to stop recording if the DVR is recording.
2 Backup button: Press this button, the DVR enters the backup menu (Fig3.3.7 USB backup). The details will be given in Chapter 3.3.3: BACKUP 3 Information button: Press this button to display status information of the DVR on the screen (Fig3.3.2 Status view). 4 Number button: These number buttons are used for selecting channels and other functions. 5 Full-Screen display mode. You can use CH+ or CH- button to switch the channel. This also can be done by pressing number buttons.
10 Search button: Press this button to enter to recording search page 11 Upward 12 Leftward 13 Rightward 14 Downward 15 SR is for Reverse when the DVR plays record while SF is for Forward 16 Change the channel one by one, “-” is used to change the channel from 16 to 1, and “+” is for changing the channel from 1 to 16 17 Fast reverse(There are seven options of speed to choose: 2X, 4X, 8X, 16X, 32X, 64X, 128X ) 18 Play 19 Fast forward(There are seven options of speed to choose: 2X, 4X,
22 Pan/Tilt control 23 Audio switch 24 Log file button 25 Picture in picture: select the channel to display as small picture first, and then press PIP button to enter PIP mode, the background picture is the next channel. For example, If the user selects channel 10 first, and then press PIP button, the screen will display as the Fig2.1.1 PIP showing. If the display mode is PIP now, press the number button to select the small picture.
Whether the battery’s anode and cathode are in the correct position or not The battery is ran out of Whether there is barrier between the Remote controller and DVR or not Whether there are some signals transmitted by other devices disturbing the Remote controller or not Attention: If the possibilities above are excluded, please contact with vendor to change the remote controller 11 5 6 7 8 10 9 Fig2.1.1 PIP 2.6 Alarm cable connection Example of alarm output connection: 28 10 11 Fig2.1.
Attention: The alarm output is TTL high level control. The connection method is described in details in the picture above. This DVR can carry sixteen sensor alarm input equipments and four alarm output equipments. There are two types of alarm input: Voltage input (5V and 0V) The low electrical level alarm of DVR is required if the usual voltage output is at high electrical level (5V) and alarm is set at low electrical level (0V).
Open/Close input N.O: Normal open. It will be closed when triggered. DVR must be set as low voltage alarm; N.C: Normal close. It will be opened when triggered. DVR must be set as high voltage alarm.
Basic operation guide 3.1 How to start the DVR Attention: Before power on the machine, please make sure the power input (110V/220V) of DVR is eligible for local power supply, if not, please move the red flipper to the correct input. If the power indicator light is off, please do as the following: If the DVR is not connected to the AC source, please connect it. Afterwards the DVR will be powered immediately. However, if the problem is remaining, please do as the next step.
machine is initialised. (The detail of admin password and user password are described in chapter 3.2.1 SETUP-SYSTEM). Input default password-“0000” to visit the setup menu if you start the DVR, assuming that you have not changed the password or you have recovered the default setting. The date, time and channel name are displayed on the screen.
ADMIN PASSWORD USER PASSWORD PASSWORD CHECK SYSTEM TIME SETUP SEQUENCE DWELL[FULL] SEQUENCE DWELL[QUAD] CAMERA NAME CAMERA STATUS LIVE CAMERA COLOR PTZF PROTOCOL PTZF ID TIME FORMAT TIME OSD FORMAT TIME STAMP FORMAT CURRENT STATUS VIEW VGA PREQ CHANGE SOFTWARE UPDATE DEFAULT SETUP SPOT DWELL MENU SPOT QUAD DWELL REC PROPERTY VIDEO STANDARD REC OPTION RECORD EVENT REC TYPE STORAGE NETWORK NET PASSWORD DELETE REC NET CLIENT PORT LOCK/UNLOCK REC NET CLIENT ID DELETE ALL REC NET DVR ID SEN
There are two users in the origin DVR system. One is Admin which has highest priority to set system’s configuration and whose password is “0000”, the other is common user which is just allowed to see the live play and the playback picture. And it does not have the right to change its password, which is done by Admin users. Operation: Press the Menu key and enter the ADMIN password, and then you will see the setup menu (Fig3.2.1 Setup menu).
Press the “Enter” key to enter the sub-menu and press the “Menu” key to get back to the main menu. 3.2.1 SETUP-SYSTEM The menu is as above: (Fig3.2.2 System setup) ADMIN PASSWORD: Administrator password is initialized as “0000”, only the administrator has the right to change it which is comprised of four numbers between 0 and 9 (Fig3.2.3 Setup admin password). USER PASSWORD: Common user password is initialized as “0000” as well.
administrator is authorized to change it which is comprised of four numbers between 0 and 9. PASSWORD CHECK: If you choose “ON”, users have to input the password before entering menu. You can setup the DVR’s configuration if you enter the administrator password. And the common user password just allows you to the check the live image or saved record; if you choose “OFF”, there is no limitation on configuration. Anyone can enter the system directly without password. (Fig3.2.
BOTTOM-BLACK: Time is displayed at the bottom in black OFF: There is no time displayed in the play back mode. CURRENT STATUS VIEW: Choose “ON”, there will be some information appearing on the screen. For example, HDD quantity, used ratio of HDD, record mode including manual/alarm/motion etc… Choose “OFF”, there is no information on the screen. VGA PREQ CHANGE: (Fig3.2.7 VGA frequency change) There are two options to choose: 50Hz and 60Hz. Please choose a suitable one for VGA monitor.
SOFTWARE UPDATE: (Fig3.2.
Update firmware: Make sure the updating firmware is in the USB disk Do not power off the DVR during updating; Press “ENTER” button to start updating. Then the system will check the updating firmware When the updating firmware is found O.K., the system starts to update. Update process: Erase the former file; Check the space for update; When the space is ready, the software update starts, the percent of update is in the right.
about two minutes to update. When the erase, blank check and update are done, system will check the new program which is written just now. After the program check is done, the system will restart. So far, USB update is over. NETWORK UPDATE: The update information is in network, please choose this option Server IP: The IP address of the network where the firmware is in. File name: The file name of the firmware.
CAMERA NAME: Name of the channel. It is comprised of the English letters from “a” to “z” or the numbers from “0” to “9”. CAMERA STATUS: If you choose “SHOW”, this image will be displayed on the screen. If you choose “HIDE”, the image will not only be displayed on the screen in live status but also in playback status. When the user plays back this record, setup this option as “SHOW”, the image hided in live status will be displayed. CAMERA COLOR: Modify channel color, contrast and bright. (Fig3.2.
are seventeen options for users: PELCO_D-2400, PELCO_D-9600, PELCO_P-4800, PELCO_P-9600, SCC641-9600, SCC641-19200, SK2161-9600, CNB_102-9600, ADTECH-4800, 15-CD51M-2400, Chubb iSD-9600, COP1-2400, COP1-4800, COP1-9600, COP1-19200, COP2-9600, 15-CD51M-2400, DSC230-9600 PTZF ID: Setup the PTZF address, you can choose from “000” to “255”. SPOT DWELL: 16 channel pictures circulate from 1 to 16.
SPOT QUAD DWELL: Channel-switching circulates from quad 1 to quad 4 (The order is: channel 1,2,3,4→channel 5,6,7,8 →channel 9,10,11,12→channel 13,14,15,16→channel 1,2,3,4→…), press “Enter” button to get access to the configuration setup menu to modify the interval time between two sets of pictures switching. The user can use the number buttons to choose the options—from“0” to “9” seconds. VIDEO STANDARD: Setup the video style. There are four options to choose: AUTO-DETECT, SWITCH, NTSC, and PAL.
maximum is 4. The record resolution is 360*288(PAL)/360*240(NTSC), there are seven frame rates to choose: 0, 1, 2, 4, 8, the maximum is 8. Attention: These three factors above decide the quality of picture and the use ratio of HDD. SETUP- REC OPTIONS: Setup of record option (Fig3.2.15 Setup record option) RECORD CONTINUOUS: If you choose “ON”, DVR records continuously in HDD recycle mode. If you choose “OFF”,this function is disabled.
records continuously. If the alarm record occurred, the DVR remains recording continuously and you can find the alarm event through “event search” or “file search”. PLAY DEINTERLACE: Interlace scan and play. If you choose “ON”, the DVR will play back after an internal of line. If you choose the “OFF”, this function is disabled. Attention: This function is more useful in VGA output mode. WATER MARK: If you choose “ON”, this function is active.
Backup. If you choose “OFF”, this function is disabled. SETUP-REC-EVENT: Setup of the event record (Fig3.2.16 Setup event record) MOTION DETECTION (Fig3.2.17 Setup motion detection): AREA: This is the detection area setup There are three options to choose: ALL, PART, OFF ALL: All area will be detected. PART: The part selected will be detected. Use the “Up” “Down” “Left” and “Right” to choose the part needed to be detected and use enter key to select/cancel the part.
[SETUP-REC-EVENT(S/D)] Fig3.2.18 Setup sensor detection SENSOR DETECTION: Each channel matches a relevant Sensor, for example, Channel 2 is linked to Sensor 4, if the Sensor 4 gives alarm, the alarm information will be given on the picture by channel 2 (Fig3.2.18 Setup sensor detection), the “□” means that the channel can not be detected, “V” means that the channel can be. OPTIONS: (Fig3.2.19 Setup record time) POST-RECORD TIME: The length of the record time after alarm triggered.
choose: 2 seconds, 4 seconds, 6 seconds, 8 seconds and10 seconds. POP-UP SCREEN: If you choose “ON”, the image will be in full screen when the DVR gives alarm. If you choose “OFF”, this function is disabled. SETUP-SCHEDULE-REC: Setup of schedule record (Fig3.2.20 Setup schedule record) Press enter key to visit the menu (Fig3.2.21 Setup schedule record time). “O” means unselected, “V” means selected. Use enter key to switch the status and use menu key to get back to upper level menu.
[SCHEDULE REC-CH 4] SU MO TU WE TH FR SA ALL DAY AL Fig3.2.21 setup schedule record time 2 1 “0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3” means: “0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23”— the 24 hours in a day. The shortest schedule record interval is one hour. For example, if the first “2” is chosen at abscissa axis, “MO” is chosen at ordinate axis, which means the DVR starts to record at 2:00 AM on Monday and till 3:00 AM; the record will last for one hour.
Press enter key to visit the menu, information is given below (Fig3.2.23 Information of deletion) “DELETE FILE 0171 200 60407_170000 15AS D U ARE YOU SURE? [ENTER]→ YES [MENU]→ NO” Press enter key to delete this record or press menu key to quit deleting “0171 200 60407_170000” is a record name. “U” means unlock, if “U” is displaced by “L”, this record is locked and can not be removed. Please refer to Appendix C for the abbreviations explain.
LOCK/UNLOCK: Lock/unlock the record. Use enter key to change the status (Fig3.2.24 Lock/Unlock file). If the file is locked, then the record can not be deleted or overwritten even though the HDD is full. DELETE ALL: If the DVR is recording, the system will remind “DELETE ALL STOP RECORDING AND TRY” Once the recording is stopped, the system will send reminder as: (Fig3.2.
[ENTER]→ YES [MENU]→ NO” (* represents A,B,C,D) Press enter key to format the HDD, Press menu key to cancel this operation. Attention: The format time depends on the HDD capability, bigger HDD takes longer time. Normally, a 40G HDD takes about eighty seconds. If CD/DVD driver connected to ATA interface, there will be three HDDs and one CD-ROM displayed. 3.2.5 SETUP-NETWORK (Fig3.2.
STATIC: Static IP address. Push “Up” “Down” “left” “Right” to move the cursor among the digits and push ADD or DEC key to modify the IP address. (Fig3.2.28 Setup static IP). DYNAMIC: Dynamic IP address. Press enter key to visit the menu, the system will display “Please wait” for a while. Then, the IP address which is assigned by network will be displayed on the screen. If the DVR failed to connect the network, it will display the information below: (Fig3.2.
The local area network has DHCP server The DVR can get IP address automatically from internet PPPOE: Connect to network by ADSL modem. “Name” is your ADSL account and “Auth” is your password. DDNS (Fig 3.2.
Dynamic domain service. To use this function, user need to get a domain from the ISP, whose protocol is packed in this DVR, as above list .Please note that the actual ISP list may be different from each Vendor, please consult your local vendor on how to get the domain if different from below example. Take the “dns2p.com” as example to introduce: Register Register in the web. Fill out the IE address column with www.dns2p.com and Click to enter the website.
Login Return to home page after registering successfully. Click “Account manager” in the right of home page to login.
Username is User ID set before, which is “abc”. Password is set before, which is “123456”. Click “Enter” button after filling out. Domain setup Click the “Domain management” in the left to setup the domain. Enter the domain in the blank and click “submit” button, the system will pop up a dialogue to show that add domain successful. For example, set “dvr” as the domain.
The length of probationary period is one month. If user wants to use it over one month, please click the “Buy now” in the right of home page to pay for it. Setup in the DVR (Fig 3.2.30 DDNS) DOMAIN: The domain is set in chapter 3. —Domain setup. According to the example before, the domain is “dvr.dns2p.com”. USER ID: The user name of register, which is ser in chapter 1. —Register in the web. According to the example before, the user ID is “abc”. GROUP ID: The name of the computer workgroup.
If the connection fails, the system prompts: Check the network and the information before, and then try again. Application Connect the DVR to internet and fill out the IE address column with “*.dns2p.com” to visit the web client of DVR. Furthermore, user can fill out the address column of net client with “*.dns2p.com” to remote surveillance. “*” is the domain set in chapter —Domain setup. According to the example before, fill the IE address column with “dvr.dns2p.com”.
Port 1 is used for logon; Port 2 is used for controlling the DVR; Port 3 is used for live surveillance; Port 4 is used for backup; Port 5 is used for playing back. NET CLIENT ID: The default ID is “NetUser”, the user can set other four ID and password for viewing through network. (Fig3.2.31 Net client ID).The login-ID and the password are composed of the letters or number at random. Only the ID set here or the default ID can be used in the remote viewer.
other IP access the DVR. NETWORK THROUGHPUT: To setup the transfer speed of DVR in the network. There are nine options to choose: unlimited, 64KBPS, 128KBPS, 256KBPS, 512KBPS, 1MBPS, 2MBPS, 4MBPS, 10MBPS. User can choose the option according to the demand (Fig3.2.33 Setup net work throughput). 3.2.6 SETUP-SENSOR/ALARM (Fig3.2.34 Setup sensor/alarm) SENSOR TYPE Press enter to visit the next level menu and there are two options to choose: NO and NC. “NO” means normal open.
“NC” means normal close. If “NC” is chosen, the DVR will give the alarm if the alarm is at high level. ALARM MOTION MANAGER (Fig3.2.35 Alarm motion manager) “□” means unselected, “V” means selected, “Abscissa” means the channel number, “Ordinate” means annunciator number. Every channel is able to trigger multiple alarms. For example, if user selects alarm 1, alarm 2 and alarm 3 for channel 1, then once there is motion detected in channel 1, alarm 1, alarm 2, and alarm 3 send alarm signal in the same time.
channel 3 for alarm 1, then any of the 3 channel detects motion event, alarm 1 will send signal. ALARM SENSOR MANAGER (Fig3.2.36 Alarm sensor manager) “□” means unselected, “V” means selected, “Abscissa” means the sensor number and “Ordinate” means annunciator number. Every sensor is able to trigger multiple alarms. For example, if user selects alarm 1, alarm2 and alarm 3 for sensor 1, then once sensor 1 is activated, alarm 1, alarm 2 and alarm 3 send alarm signal in the same time.
for alarm 1, any of the 3 sensors is activated, the alarm 1 will send alarm signal. ALARM BUZZER (Fig3.2.37 Alarm buzzer) ON: Start the buzzer when DVR gives alarm OFF: The buzzer will not be triggered when DVR is alarming ALARM OUTPUT (Fig3.2.38 Alarm output) ON: Alarm on. Only when the alarm output is on, the DVR will give alarm when the sensor is triggered or the motion event occurs. OFF: Alarm off. The DVR will not send alarm when output is off.
ALARM OUT PERIOD (Fig3.2.39 Alarm output period) Alarm continuing time. There are five options to choose: 30 seconds, 1 minute, 3 minutes, 10minutes and Continuous. 3.2.7 SETUP-AUDIO “■” means unselected, “V” means selected, “Abscissa” means the channel number and “Ordinate” means audio output number. (Fig3.2.
There are four audio input ports and one audio output port in all. One audio input matches one channel. For example, if user selects audio A for channel 1, channel 1 will record audio A. 3.3 Function Press the Function button to enter the basic function menu (Fig3.3.1 Function menu), which contains the following items: STATUS AUDIO BACKUP PAN/TILT ZOOM/FOCUS LOG LIST 3.3.
interface, there will be three HDDs and one CD-ROM displayed. [STATUS] S/W VER: V1.0.10-tv_16 (06/05/08 10:07) [HDD] A: 150G(63%) B: NONE C: NONE D: NONE NETWORK: MAC: 00.0E.B5.00.06.32 DDNS: SERVER (null) FAIL [REC] SIZE 720*576 CH RA QUAL CH RA QUAL CH RA QUAL CH RA QUAL 1 2 BEST 5 2 BEST 9 2 BEST 13 2 BEST 2 2 BEST 6 2 BEST 10 2 BEST 14 2 BEST 3 2 BEST 7 2 BEST 11 2 BEST 15 2 BEST 4 2 BEST 8 2 BEST 12 2 BEST 16 2 BEST Fig3.3.2 Status view 3.3.
3.3.3 BACKUP& VIEW BACKUP Backup Press the Backup button (Fig3.3.3 Setup backup). This DVR support five media types: CD-R, CD-RW, DVD-R, DVD- RW, USB-MEMORY (Contain USB disk and mobile hard disk), and support backup to DVD-RW, CD-RW, internally and as well as USB externally. Please refer to list of compatible DVD-RW, CD-RW, which may be updated at times. MEDIA TYPE: Press Enter button to access the next menu (Fig3.3.
backup in CD-R, please choose CD-R; if you plan to backup in CD-RW, please choose CD-RW, etc… BACKUP BASE: If you want to search the file needed to backup by file name, please choose FILE; if you want to search the file needed to backup by time, please choose TIME. Each operation method is in the Chapter— START. CHANNEL: If you want to backup the four channels, please choose ALL, if you want to backup several channels of the four channels, please choose PART.
If the backup base is “FILE”, the “START” choose menu is as Fig3.3.5 Backup start (file) showing. If the backup base is “TIME”, the “START” choose menu is as Fig3.3.6 Backup start (calendar) and Fig3.3.7 Backup start (time) showing. First, choose the date, second, choose the time. [BACKUP-TIME] USB BACKUP USB BACKUP HOUR: MIN: : : 000000 TIME 50% Fig3.3.8 USB Backup process END: The backup’s end, the setup method is the same as the START.
screen in the same time with backup. The USB backup process is as the Fig3.3.8 USB backup process showing, that is the same as backup with the CD/DVD driver. When the backup is over, a dialogue box will pop up. If the user backup in the USB memory, the sentence in the dialogue box is as following: “FLASH BACKUP OK” So far, the backup is completed. Cancel If the user wants to change the backup file, please move cursor to “CANCEL” and press “ENTER” button to cancel the file selected before.
: Play : Stop : Step backward : Pause : Fast backward : Step forward : Fast forward : Verify the record is changed or not : Snap shot : Volume control : Number button / / / :1-channel/4-channel/9-channel/16-channel mode You can use number button to choose the channel which you want to see.
Particular introduction of W.M Check, SnapShot. W.
After a few minute, the result will pop up. If the backup file is changed or moved, the system will pop up “Watermark Check Fail”, if the backup file was not changed or moved, the system will prompt “Watermark Check Ok”. SnapShot: Click SnapShot button, a picture pops up for saving or printing. The user can select directory to save, and also can print it directly. Snap Again: If you want to snap the next picture, Please press the “Snap Again” button.
please press CANCEL. 3.3.4 PAN/TILT Move cursor to PAN/TILT in the function menu, press Enter button to access this menu (Fig3.3.9 PAN/TILT) to control the Fast Speed Dome. The particular operation is as following: Switch to the channel which connects to the Fast Speed Dome video output. Through the “Up” “Down” “Left” “Right” button to control the Fast Speed Dome to swing up, down, left or right, press “Enter” button to stop swinging.
controller. PAN/TILT ZOOM/FOCUS Z+ F+ AUTOPAN ENTER <> Fig 3.3.9 PAN/TILT FZ<> Fig3.3.10 ZOOM/FOCUS 3.3.6 SEQUENCE Press “SEQ” button to enter the sequence play status. If the current menu is the image of a single channel, press “SEQ” button to play the sixteen channels one by one circularly.
four channels by four channels circularly. 3.3.7 LOG LIST Press the Log button on the remote controller, the system will enter the setup menu of log file (Fig3.3.11 Setup log file). LOG FILE: If you choose ALL, the following options in the picture will be displayed, which contains: MOTION, SENSOR, ALARM, V-LOSS, SYSTEM, HDD, FLIE, DB, POWER, NET.
should choose the option needed manually. There is a white dot in the blank after the option selected. FROM: The beginning time of the log file, you can use the number key to change the time. TO: The end time of the log file, you can use the number key to change the time. Press the OK if you setup above over, the system will enter the event log view (Fig3.3.12 Event log view): Use “Up” “Down” to move the cursor to the log file needed.
3.4 Search record Press the “Search” button on the remote controller, there are three search modes which will be displayed on the screen (Fig3.4.
search. TIME SEARCH: Attention: All the record can be searched in this menu. Operation: Date choose: Press enter to access the CALENDAR TIME menu, Use “Up” “Down” “Left” “Right” to move cursor to the date needed to search.(Fig3.4.1 Date choose). The time which had event record is shown as yellow font. <<2006-05>>: Year-Month <<: Backward, when the cursor moves to this sign, it will be in yellow, then press enter to make the month backward.
Press Enter button to view the record chosen, the “Forward” “Backward” “Play/pause” buttons can be used to control the record. Press “stop” button to get back to live picture. EVENT SEARCH Attention: Only the alarm event and motion event record can be searched in this menu. Operation: Select the date, whose method is the same as TIME SEARCH. The time which had event record is shown as yellow font. Press “Enter” to access the event menu after selecting time. (Fig3.4.3 Event choose).
“Forward” “Backward” “Play/pause” buttons can be used to control the record. Press “stop” button to get back to live picture. If there are too many event lists, user can move to the page needed though “PGUP” “PGDN” “LAST” “FIRST”, the meaning of these signs and shortcut keys are in the following table. [SEARCH-TIME] HOUR: MIN: TIME: 00: 00: 00 Fig3.4.
FIRST To the first page Forward button FILE SEARCH Attention: All the record can be searched in this menu. Operation: Select the date, whose method is the same as TIME SEARCH. The time which had event record is shown as yellow font. Press “Enter” to access the play file list. (Fig3.4.4 File search) Analyze the record information. Take one of the file records information as example.
Select the record and press “Enter” button to view this record. Use “Up” “Down” to choose the file record, Press enter button to view the record chosen, the “Forward” “Backward” “Play/pause” buttons can be used to control the record. Press “stop” button to back to live picture If the event file list is too much, user can move to the page needed though “PGUP” “PGDN” “LAST” “FIRST”, the meaning of these signs and shortcut keys is in the table above. The record was divided into many sections automatically.
Attention: There is no setup menu in the screen of spot monitor.
Appendix Appendix A Main Standard & Parameter chart Model 16Channel VIDEO Input Channel 16CH Input Level 1.0Vp-p±10% Composite, 75Ohm Balanced Video Standard Auto / NTSC / PAL Main TV Out 1.
Function Auto Sequence Screen Split, PIP AUDIO Compression ADPCM Audio In / Out 4CH /1CH Input Level TBD(0.5~1.
Speed 5400RPM, 7200RPM Type EIDE compatible SEARCHING & PLAYBACK Searching Method Time, Event, File REMOTE SURVEILLANCE Monitoring Environment Client Software, Web Browser ALARM Sensor Input 16Ports Alarm Output 4 TTL-Out(Programmable), Terminal Motion Detection Available For Each Camera Multi Detection Level CONNECTOR Video Input BNC 16Ports Main Monitor Output BNC 1Port Spot Monitor Output BNC 1Port S-Video (Main TV) BNC 1Port (4Pins mini DIN) VGA Output BNC 1 Port (15Pins female DS
External Control (RS-422/485) Terminal Block Sensor Input Terminal Block Alarm Output Terminal Block PTZ (RS-485) 2Pins Terminal Block Ethernet RJ-45, 10/100Mbps USB 2.0 2Ports ELECTRICAL Power Source 115~230VAC (50~60Hz) Power Consumption TBD(App. 50 ~ 60Watt) BACKUP Digital Backup Network, External CD/DVD RAM, USB Storage External CD/DVD RW USB 2.
Appendix B Record capability --how much capability does record engross per hour PAL NTSC Picture Capability Total Frame Rate Capability Resolution Total Frame Rate Quality Resolution Best 720*576 3.80G 720*480 3.75G 25F/S 30F/S High 720*576 1.91G 720*480 2.34G 25F/S 30F/S Normal 720*576 0.96G 720*480 1.20G 25F/S 30F/S Low 720*576 0.83G 720*480 0.80G 25F/S 30F/S Best 720*288 4.10G 720*240 3.94G 50F/S 60F/S High 720*288 2.60G 720*240 2.42G 50F/S 60F/S Normal 720*288 1.28G 720*240 1.
Appendix C The meaning of some abbreviation Words Meaning Words Meaning D 720*576(PAL)/720*480(NTSC) H 720*288(PAL)/720*240(NTSC) C 360*288(PAL)/720*240(NTSC) NT The event of network U Unlock L lock MD Motion detection SD Sensor detection PW The event of power on occurred VL Video loss AL Alarm DB The data base recurred or united HD The event about HDD occurred TM Time change SY The event of system setup or the system reset FL The event of file occur or get rid of DVR
MPEG4 Standalone DVR Password reset instruction: To the password reset, Press : [INFOR] + [AUDIO] + [SEARCH] + [STOP] + [4X4] on the remote control. Select password reset and press [ENTER].
Manual Of Remote surveillance *This manual is tailored for 4/9/16 channels digital video recorder *This manual takes 16-channel digital video recorder as example 1
Table of Contents 1 IE remote operation..................................................................................................................................... 3 1.2 Login ................................................................................................................................................. 5 1.3 Particular operation of the IE Client................................................................................................... 9 2 Remote software operation ........
Remote live surveillance This DVR supports remote surveillance through LAN, Intranet and Internet. After connected to the network, the DVR function as a server. Any connected computer, via Internet or LAN, can view the live surveillance, control PTZ in the active-x file downloaded from IE browser, and can playback/backup the recording files from the client software installed in the computer The DVR supports three remote users’ login simultaneously.
software, the dialogue box is as following: Click “Install” button to install IE client. If click “Don’t install” button, user can not operate DVR via IE. Uninstall If user wants to uninstall IE-Client, please do as following steps: ① Click “properties” of internet explorer ② Click “Settings” of “Temporary Internet files” ③ Click “view objects” to open the folder of the IE-Client ④ Delete “VS_MK2Web control”.
1.2 Login Read the IP address from the DVR and fill out the IE address column with it.
to visit the Web Client of DVR and a dialog box pops up (Fig 1.1.1 Login).
Enable Overlay: If user’s VGA card supports overlay function, the display performance works better with this option selected. Users have to disable this function unless user’s VGA card supports it. Enable Audio: If this option is selected, the live audio will be transmitted to the long-distance surveillance PC. 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, and 16: The channel selected is displayed on the screen.
192.168.0.155 192.168.0.155 CAM1 CAM1 2006-07-10192.168.0.155 2006-07-10 192.168.0.155 11:28:01AM CAM2 CAM2 11:28:01AM 4FPS 4FPS 95KBPS 95KBPS 192.168.0.155 192.168.0.155 CAM1 CAM5 4FPS LIVE 95KBPS LIVE 95KBPS 2006-07-10 192.168.0.155 2006-07-10 192.168.0.155 11:28:01AM CAM2 11:28:01AM CAM6 4FPS 4FPS 95KBPS 95KBPS 192.168.0.155 192.168.0.155 CAM1 CAM9 4FPS 95KBPS LIVE LIVE 95KBPS 2006-07-10 192.168.0.155 11:28:01AM 2006-07-10 192.168.0.155 CAM2 11:28:01AM CAM10 4FPS 95KBPS 4FPS 95KBPS 192.168.0.
1.3 Particular operation of the IE Client ⑴ Alarm: If the DVR sends motion alarm, the channel name flashes on the screen and a word is displayed, “MOTION” (Fig1.1.3 Motion alarm). If the DVR sends sensor alarm, the channel name flashes on the screen and a word is displayed, “SENSOR”. ⑵ Screen mode: It enables the user to control the screen mode and size.
Button Screen mode 1-channel 4-channel 6-channel 8-channel 10 Screen
9-channel 10-channel 13-channel 16-channel ⑶ Rotation/Next : Rotation. If you press this button, the picture will be displayed from channel 1 to channel 16 in turn.
: Next. Switch the pictures from current channel to next channel. ⑷ Sound volume : The volume is from low to high when the bar is shifted from left to right. You can click and or drag the bar to tune. the ⑸ PTZ With the PTZ camera, the user can change PAN, TILT, ZOOM, FOCUS and IRIS in remote site. ① This button is for PAN/TILT and ZOOM adjustment. The button of ZOOM-IN and the button of ② 12 makes is for ZOOM-OUT. This button is for the FOCUS adjustment, and mean short and long each.
③ : This button is for the IRIS adjustment. If the light situation of the area where camera is located is too strong, press is located is too weak, press ④ to decrease volume of light, and the light situation of the area where camera to increase amount of light. : Press this button to set the PTZF (Fig1.1.4 PTZF setting) Internal: If the PC is connected to the DVR in the same local area network, you have to choose Internal and do not need to reset the configuration.
In the same way, the protocol set in the Fast speed dome should be PELCO_D, the baud rate should be 2400kpbs, and the address should be 01. ⑹ Channel You can choose the channel directly which you want to see through the number button from 1 to 16.
⑺ Disconnect/Connect : Press this to terminate the connection between DVR and the IE client. : Press this button to regain the connection between DVR and IE client. Attention: These two buttons do not appear at the same time. When “Disconnect” shows, it means the IE client is connected with DVR, when “Connect” shows, it means the IE client not connected.
2 Remote software operation Remote software refers to Network Client, hereinafter abbreviated as “Net Client” Function: Live video and audio; Remote PTZF control; Remote playback and record. 2.
CAM1 CAM2 2006 07 10 10:52:14 CAM5 CAM3 2006 07 10 10:52:14 CAM6 CAM4 2006 07 10 10:52:14 CAM7 2006 07 10 10:52:14 CAM8 10 2006 07 10 10:52:14 CAM9 2006 07 10 10:52:14 CAM10 2006 07 10 10:52:14 CAM11 2006 07 10 10:52:14 CAM12 9 2006 07 10 10:52:14 CAM13 2006 07 10 10:52:14 CAM14 2006 07 10 10:52:14 CAM15 2006 07 10 10:52:14 CAM16 6 2006 07 10 10:52:14 2006 07 10 10:52:14 2006 07 10 10:52:14 8 7 2006 07 10 10:52:14 5 17
The button description: Number 18 Icon Description Function Live control Press this button to view the live picture of the DVR, and the user can control the PTZF equipment in the same time. Remote-playback Press this button to playback the record in the DVR via network. File backup Press this button to backup the file from the DVR to computer. Local-playback Press this button to play the file in the mobile disk or local disk of the computer. Volume Control Adjust the volume.
Connect/ Disconnect Option Select Channel Select display mode: full screen / Quad / 9-channel / 16-channel Connect/disconnect the connection between DVR and Net Client. Setup the options, such as: control port, initial mode, and audio connect. Choose the desired channel.
2.2 Connection (1) Click “connect” icon in the main window of the Net Client to enter the connection setup menu. (2) Input Address & ID / Password. The address is the IP address of the DVR, which is set in the TYPE menu, which is the submenu of the NETWORK menu of the DVR. The ID and the password are set in the NET CLIENT ID, which is the submenu of the NETWORK menu of the DVR.
(3) Then, click “Connect” button. 2.3 Live Press LIVE button in the main window of the Net Client, the live picture would display in the screen and the PTZF control button displays at the same time, whose meaning is showing in the following picture. PAN/TILT controller: Click the direction button to swing the Fast speed dome. For example, click leftward button, the camera of the Fast speed dome will swing to left. Zoom controller: Click the “+” button to zoom in and click “-” button to zoom out.
2.4 Remote playback And then, use the following button to control playback.
: Stop : Pause : Reverse by frame : Play : Fast Backward : Forward by frame : Fast forward Attention: ⒈ The date is around by red line is today; ⒉ The date which had record is shown as boldface. ⒊ The time which had record is shown as the design of blue alternate with white grillwork below the hour and minute axes.
2.5 Backup And then, a dialogue box pops up and the backup begins.
The backup file name, backup progress and the size of the backup file are shown in the dialogue box. When the backup progress is over, this dialogue box will disappear. The backup file is the special format which can be played by the Net Client only. Attention: The speed of the network and the size of the backup file decide the length of the backup time together.
2.
The file recorded by this DVR is postscript file, whose suffix is “.ps”. Any postscript file in the HDD or CD/DVD can be played back, containing the HDD or CD/DVD driver connected to ATA and USB interface of computer. 2.7 Volume Control : The audio is disabled. : The audio is on. The volume is from low to high when the bar is shifted from left to right.
2.8 Snap shot : Capture the picture of the record and the live picture. Select the channel whose picture is ready for saving or printing first. And then, press the “Snapshot” button. A window pops up for saving or printing. The user can select directory to save, and also print it directly. If you want to snap the next picture, please press the “Snap Again” button.
29
2.9 Option Press button to setup the “control port”, “stream port”, “initial mode” and “audio connect”. Control port/stream port: The port must be set as the same with the DVR, and these ports should be opened. Initial mode: If the DVR is 4-channel, please choose 4; if the DVR is 9-channel, please choose 9; If the DVR is 16-channel, please choose 16. Audio connect: Only this option is chosen, there is audio output in the Net Client. 2.
(Y/N)”.Press “Y” key on keyboard or click “Yes” button to exit. Press “N” key on keyboard or click “No” button to return to the main menu. Attention: These two buttons do not appear at the same time. When “Disconnect” shows, it means the net client is connected with DVR, when “Connect” shows, it means the net client not connected.