Technical Data Bulletin

Copper Sealtite 2000 07 65 13 - 4
C. Ensure there are no slopes to form pockets or prevent free drainage of water to exterior
surfaces of wall.
3.3 INSTALLATION
A. Install flashing in accordance with manufacturers instructions at locations indicated on the
Drawings.
Specifier Notes: Edit the following sentence. Include the section number for the masonry installation.
B. Masonry: Install masonry as specified in Section 04 2__ ___.
C. Horizontal Masonry Surfaces:
1. Lay flashing in slurry of fresh mortar and top with fresh full bed of mortar.
2. Carry flashing through wall as indicated on the Drawings and leave exposed at exterior for
inspection.
3. After inspection, cut flashing flush with exterior masonry.
D. Vertical Masonry Surfaces:
1. Apply sealant to surfaces receiving flashing to hold flashing in place until masonry is set.
2. Secure flashing in back wall mortar joint or reglet as indicated on the Drawings.
E. Foundation Sill Flashing:
1. Lay flashing for foundation sills in slurry of fresh mortar and top with fresh full bed of
mortar.
2. Leave flashing flush with exterior face of masonry and turn up on inside a minimum of 2
inches or carry upward across cavity a minimum of 6 inches.
3. Secure flashing in back wall in reglet or mortar joint.
4. Bring flashing a minimum of 10 inches up columns and secure, where sill and columns
meet.
F. Cavity Wall Flashing:
1. Lay flashing in slurry of fresh mortar and top with fresh full slurry of mortar.
2. Leave flashing flush with exterior face of masonry wall and carry through wall, upward
across cavity a minimum of 6 inches, and secure in back wall mortar joint or reglet.
G. Spandrel Flashing: Start spandrel flashing from outside toe of shelf angle, go up face of beam,
and through wall turning up on inside a minimum of 2 inches.
H. Parapet or Copings:
1. Lay flashing for parapets or copings in slurry of fresh mortar and top with fresh full bed of
mortar.
2. Install flashing flush with exterior and interior faces of masonry wall.
I. Head and Sill Flashing:
1. Start flashing flush with outside of wall or lintel angle and carry through or up wall as
indicated on the Drawings.
2. Extend flashing 6 inches beyond each side of opening and turn up at sides forming pan.
3. Fold corners; do not cut.