1.5. Operation
A fan sucks the air required for the combustion through the air
feed canal (A). Because the combustion air in the venturi
sucks an under pressure, the correct amount of gas (G) is
automatically added to the combustion air.
The flammable gas/air mixture thus obtained is fed to the
burner, via a mixing chamber, to be ignited at the surface of
the burner by a ceramic glow plug. The hot combustion gases
are efficiently fed through the heat exchanger, where they
give their heat to the water. The flue gases are fed outside,
through the flue tube (F), into a flue tube exhaust canal.
The condensation water (H
2
O) thus obtained is discharged
into the sewer.
1.6. Boiler types
Coopra 40C
High efficiency boiler for central heating
only.
The Coopra boiler is a heating unit with compact dimensions
and a very high efficiency, with versions for domestic and
small commercial use for central heating.
The type plate, which specifies the type of gas etc. to be used,
for which the unit is set, is on the left side of the unit.
The unit is fixed to the wall with the aid of a separately
delivered assembly bracket or rear cabinet.
1.6.1. Burner assy
1.6.2. Primair heat exchanger
1.6.3. Venturi
1.6.4. Pump