Installation manual
Coopra Advanced Heating Technologies Installation manual 40 EN
15
3.5.2. Modulating room thermostat (if applicable).
Connect to terminals (1) and (2)
The modulating room thermostat must be fitted in the same
building as the unit.
Strip about 5 mm off the insulation of the wires of the room
thermostat. Stick the stripped ends of the wires into
connections (1) and (2) of the connection block. Make sure
that the wires do not make a short circuit. Firmly tighten the
screws in the connection block.
When using a modulating thermostat, the plug on the printed
circuit board must be connected with the correct polarity.
To reach the printed circuit board, the black casing must be
opened. Connect the plug for the relevant modulating space
unit to terminal a, b or c, according to the following
photograph.
a White
Connection for an on/off
room thermostat
24 Volt
b Red
Connection for RS30 with
Coopra protocol
EBV space
regulation
c Blue Opentherm connection
Honeywell or TEM
space regulation
3.5.3. Connection for the external temperature sensor (if
applicable).
Connect to terminals (3) and (4)
If an external sensor is connected, this temperature sensor
must be an NTC with a resistance of 12 kOhm at 25°C.
Strip about 5 mm off the insulation of the wires of the sensor.
Stick the stripped ends of the wires into connections (3) and
(4) of the connection block, see figure 8. Make sure that the
wires do not make a short circuit. Firmly tighten the screws in
the connection block.
If an external sensor is not used, terminals (3) en (4) can
remain open.
3.6. Assembling the connection block
Connect the green connection
block in the green socket.
3.7. Placing the jacket
Place the jacket in the appropriate hooks at the top of the unit.
Let the jacket pivot until it falls over the unit. Tighten the
fastener at the bottom of the jacket.
b
a
c