TS590 Intruder Alarm Control Panel _ ~ SYSTEM OPEN 17:30 01 Jan A 1 2 3 B 4 5 6 C 7 8 9 D ENT 0 ESC Sett ing the Syst em Ent er your pa ss code XXXX th en lea v e th e pro tec t ed a re a. Unsetting the System Go dir e ct ly to t he ke yp ad and en ter you r p as scod e XXXX . Resetting Ent er your pa ss code XXXX f ollow ed by EN T the n 3. Te leph on e you r a lar m com pan y and follow th eir instr uct io ns.
Contents System Overview Introduction . . . . . . . . . . . . . . 3 Remote Keypads. . . . . . . . . . . . 4 Operating Your Alarm System Introduction . . . . . . . . . . . . . . 5 Passcodes . . . . . . . . . . . . . 5 User Types . . . . . . . . . . . . . . 5 User Menus . . . . . . . . . . . . . 5 Banner Message . . . . . . . . . . 5 Engineer on site . . . . . . . . . . . 5 Full Setting The System . . . . . . . . . 6 Unsetting the system . . . . . . . . . . 7 Part Setting The System . . . . . . . . .
System Overview Introduction The TS590 is an advanced security alarm control systems using state of the art electronics to provide comprehensive but flexible protection for both domestic and commercial premises. The system comprises of a number of components linked to a central control unit which is concealed from view but accessible for maintenance. The TS590 can monitor from 6 to 14 detection circuits. Both systems can be operated from up to four remote keypads which may be one of four types.
Remote Keypads Your alarm system can be operated from one or more remote LCD keypads, which will have been strategically located within the protected premises. The LCD remote keypad is a full function keypad and can be used to program, test, set and unset the alarm system. LCD Display - Used to show the system time along with other system messages. Green Power Indicator - Flashes if no mains power is present. Steady when mains power is present.
Operating Your Alarm System Introduction Passcodes Access to the system is gained by entering a 4 digit passcode. Every time you wish to use the system your passcode must be entered correctly. User Types The TS590 can have up to 15 separate users each user is assigned a passcode, and a user level. The user level defines what the user can access within the user menus, for a definition of each user level see “Set-up New Users” page 24.
Full Setting The System The full setting procedure can be initiated from any remote keypad (if more than one is fitted). Before attempting to full set the alarm system ensure that all movement detectors are unobstructed and all doors, and windows are secure. 1. 2. 3. From the unset (open) mode enter your passcode. After 5 seconds the exit sounder will start and the display will show the remaining exit time.
Unsetting the system The unsetting of the alarm system can be performed at any remote keypad. 1. 2. Enter the premises via the prescribed entry route and proceed directly to the remote keypad. The internal sounders generate an interrupted tone. The display will show the remaining entry time. Enter your 4 digit passcode before the entry timer expires. The internal sounders will stop and the display will show “SYSTEM OPEN”.
Part Setting The System The TS590 can have up to three predefined part set configurations. Each configuration allows the alarm system to set with one or more circuits isolated. Normally the alarm company will configure each part set option, however the master user may also configure the part sets, providing the alarm company has programmed the alarm system to allow this facility. 1. From the unset (open) mode enter your passcode. 2. Select the required part set mode by pressing [A], [B] or [C]. 3. 4.
Unsetting After an Alarm If an alarm has occurred whilst the alarm system is full or part set, the display will indicate the detection circuit that was triggered when you unset the system. Once the cause of the alarm has been established the system must be reset, see “Resetting after an alarm” on page 10. 1. 2. 3. E n t er t h e p re m i s e s v i a t h e prescribed entry route and proceed directly to the remote keypad. The internal sounders generate an interrupted tone.
Resetting After an Alarm Your alarm company will have programmed the system to be either “User Reset”, “Engineer Reset” or “Remote Reset”, consult your alarm company if you are not sure. User Reset If your system has been programmed as user reset, alarms can be reset by any user that has a valid passcode. From step (3) of “Unsetting After an Alarm”, proceed as follows: 1. 2. Enter your passcode and within 5 seconds press [ESC]. The system is now reset and back in the open mode.
Remote Reset If your system is programmed as remote reset, alarms can be reset by your alarm company or via the exchange or unique passcodes. From step (3) of “Unsetting After an Alarm”, proceed as follows: 1. The display will alternate between the circuit t hat cau s e d t h e a l a rm a n d t h e “ C a l l Engineer To Reset System” message. The internal sounders will also generate a beep every minute to remind you that the system requires resetting. 2.
User Menu 1 Introduction User menu 1 is accessed by entering your passcode followed by [ENT]. There are 12 menu options and access to these options will depend on your access level. LCD Remote ? ? ? ? + ENT User menu 1 Select Option :- 1 Bell Test Sounder.
Bell Test This option allows you to periodically test the external sounders (bell and strobe) and internal sounders. When selected each device will operate in sequence for nine seconds. 1. 2. 3. 4. From the unset (open) mode enter your passcode and press [ENT] to select user menu 1. Whilst user menu 1 is selected. Press [1] to select the bell test option. The internal sounder operates for 9 seconds, then the external sounder operates for 9 seconds, then the external strobe operates for 9 seconds.
Walk Test This option allows you to test the function of individual detection circuits without causing an alarm. As each circuit is activated the circuit number and status are displayed and the internal sounders generate a two tone “Chime” sound. Once the test has been completed the tested circuits can be reviewed in numerical order. 1. 2. From the unset (open) mode enter your passcode and press [ENT] to select user menu 1. Whilst user menu 1 is selected. Press [2] to select the walk test option.
Change Passcode This option allows you to change your own passcode. The master users can also add and delete user passcodes, see “Set-up Users” on page 24. 1. 2. 3. 4. From the unset (open) mode enter your passcode and press [ENT] to select user menu 1. Whilst user menu 1 is selected. Press [4] to select the change passcode option. Enter your new passcode then press the [ENT] key. A rising tone indicates acceptance and the system returns to user menu 1.
Enable Chime Detection circuits that have been programmed as “Chime” will generate a two-tone sound when triggered. This option allows you to select one of the four chime options: 1 Disabled Chime circuits are disabled. 2 Enabled Chime circuits are enabled at all times. 3 Enabled in P/Set Chime circuits are enabled when the system is unset or part set. 4 Enabled in Unset Chime circuits are only enabled when the system is unset. 1. 2. 3. 4. 5.
Isolate/Re-instate Shunt Group One or more circuits can be assigned to the shunt group, this is normally done by your alarm company although the master user can also configure the circuits that are assigned to the shunt group, see “Alter Shunt Group” on page 27. Once a shunt group has been defined this option allows you to isolate and re-instate the circuits that are assigned to the shunt group. Isolating a Shunt Group 1. 2. 3.
Omit Circuits Occasionally it may be necessary to omit detection circuits when setting or part setting the system. This allows the user access to the omitted area(s) when the system is set or part set. It is also possible to omit 24hr or Auxiliary circuits so that access to these areas can be obtained when the system is unset. LCD Remote Only detection circuits that have been programmed by your alarm company as “Omit” can be selected when using this option. 1.
Silent Set This option allows you to full set or part set the system silently, i.e. no exit sounder, accept for set confirmation tone. 1. 2. From the unset (open) mode enter your passcode and press [ENT] to select user menu 1. Whilst user menu 1 is selected. Press [8] to select the silent set option. LCD Remote SYSTEM OPEN 17:30 01 JAN 1 User menu 1 Select Option :- 2 3. Press [0] to silent full set , [A], [B] or [C] for silent part set.
User Menu 2 Introduction User menu 2 is accessed by pressing [ENT] whilst user menu 1 is selected. There are 10 menu options and access to these options will depend on your access level. LCD Remote ? ? ? ? + ENT ENT User menu 2 Select Option :- 1 View Circuits CCT 01 Healthy 2 Set Clock Set Clock > ---- 3 Set Date Set Date > ---- 4 5 Setup User Codes Setup users User No. > -Alter Chime Circuits Alter Chime ccts Enter CCT No.>-- 6 Alter Shunt Group Alter Shunt grp Enter CCT No.
View Circuits This option allows you to ascertain the status of each detection circuit, The status for each circuit may be as follows: Healthy The normal status of a detection circuit, i.e. door closed or detector healthy. Active This is the alarm status of a detection circuit, i.e. door open or detector in alarm. Tamper This is the tamper open circuit status of a detection circuit, i.e. alarm cable cut or a cover removed from a detector.
Set Clock This option allows you to adjust the system clock. The clock is used for providing event times in the event log and is also displayed when the system is unset or full set. 1. 2. 3. From the unset (open) mode enter your passcode and press [ENT] twice to select user menu 2. Whilst user menu 2 is selected. Press [2] to select the set clock option. Enter the new time in a 24hr format, e.g. 1700 for 5:00 PM. When the display shows the correct time press [ENT] to accept.
Set Date This option allows you to set the system date. It is displayed in a date / month format on all LCD remote keypads. 1. 2. 3. 4. From the unset (open) mode enter your passcode and press [ENT] twice to select user menu 2. Whilst user menu 2 is selected. Press [3] to select the set date option. Enter the new date in a date/month format, e.g. 1806 for the 18th June. When the display shows the correct date press [ENT] to accept. To return the system to the open mode press [ESC] twice.
Setup New Users The TS590 allows up to 15 users to operate the alarm system, each user is assigned a user type and a passcode. User 01 is the master user which has a default setting of 5678. User Types The following user types are available: 1 - Master This user type can full set, part set and unset the system. A master user also has access to all user menus and options providing the alarm company has programmed the master user for full access.
Setup New Users (Cont.) 1. 2. 3. 4. 5. 6. From the unset (open) mode enter your passcode and press [ENT] twice to select user menu 2. Whilst user menu 2 is selected. Press [4] to select the set-up new users option. Enter the user number (02 - 15) that you require to set-up, then press [ENT]. The display shows the current type assigned for the selected user, to change the user type press [1] - [8]. When the display show the required user type press [ENT] to accept.
Alter Chime Circuits This option allows you to select which detection circuits will cause a chime tone when triggered. Once programmed, users that have access to user menu 1 can select one of the four chime options, see “Enable Chime” on page 17. 1. 2. 3. 4. From the unset (open) mode enter your passcode and press [ENT] twice to select user menu 2. Whilst user menu 2 is selected. Press [5] to select the alter chime circuits option.
Alter Shunt Group This option allows you to define which detection circuits are allocated to the shunt group. Once assigned to the shunt group all circuits within the group can be isolated by any user that has access to user menu 1 option 6 (Omit Shunt Group). The shunt group can also be assigned to a user code (Shunt), this allow the group to be omitted and re-instated by entering a 4 digit passcode. 1. 2. 3. 4. 5. 6.
Print System Log The system log stores 700 events. If a printer is connected to your alarm system it is possible to print a selected number of log events. 1. 2. 3. 4. From the unset (open) mode enter your passcode and press [ENT] twice to select user menu 2. Whilst user menu 2 is selected. Press [7] to select the print system log option. Enter the number of events to be printed (001 - 700). Press [ENT] to start the printout. To cancel printout repeat from step 2 and enter “000” for the number of events.
Set-up Part Sets The TS590 can be configured to have up to three parts set modes (Part Set A, Part Set B and Part Set C). This option allows the master user to configure each part set mode. Within each part set mode you must designate which circuits will remain armed and which circuits will be omitted. When the relevant part set mode is selected the system only arms the circuits that are designated as armed and isolates the circuits that are designated as omitted. 1.
View Log The TS590 store up to 700 events in the log. This option allows you to view each event. 1. From the unset (open) mode enter your passcode and press [ENT] twice to select user menu 2. LCD Remote 2. Whilst user menu 2 is selected. Press [9] to select the view log option. 3. The display will show the most recent event, see log event codes. To navigate through the log, use the [A] and [C] keys to scroll backwards and forwards.
Log Event Codes LCD Description AC OFF Mains power removed. AC RESTORED Mains power restored ACTION ALARM Alarm activated when system is part-set. ALARM 01-14 Full alarm from circuit (01-14). AUX/BELL TAMPER Auxiliary tamper activated. AUXILIARY 01-14 Auxiliary circuit activated. BATTERY FAULT Battery fault (voltage below 10.5V). BELL TESTED External bell and strobes tested. CALL BACK No. 01-03 Modem making a call back to remote PC.
LCD Description PA ALARM 01-14 Panic Alarm circuit activated. PA CODE 00-15 Panic Alarm passcode entered (00 = Keypad PA). PANEL LID TAMPER Control panel lid removed. PART SET A/B/C System Part-Set using one of the A, B, or C buttons. PASSCODE 00-15 User passcode entered. (00-15). REM REMOVED 01-04 Remote Keypad removed from system. REM SERVICE CALL Remote service call via “Lineload” software and PC. REM TAMPER 01-04 Remote Keypad cover removed.
Enable Remote Service If your alarm system has been fitted with a modem, the alarm company can dial into the system and remotely read and write data from the control panel. For added security, your alarm system can be programmed so that a master user has to authorise the writing of data to the control panel. 1. 2. 3. 4. 5. From the unset (open) mode enter your passcode and press [ENT] twice to select user menu 2. Whilst user menu 2 is selected. Press [0] to select the enable remote service option.
Initiate Service Call If your alarm system has been fitted with a modem it is possible for a master user to initiate an upload sequence to a remote site (normally the alarm company). Once the communication link is established, the remote site can read and write data from the control panel. 1. 2. 3. From the unset (open) mode enter your passcode and press [ENT] twice to select user menu 2. SYSTEM OPEN 17:30 01 JAN Whilst user menu 2 is selected.
Circuit Text Each detection circuit can have up to 16 characters of text assigned to it. This option allows you to program / edit the circuit text.
DELAY ALARM 05 17:30 01 Jan Fault Finding Display Messages Displays Description 01 Jan There is no mains power to the control panel and the alarm system is now running on its standby battery. The system will also generate a chime tone every minute to warn you that the fault exists, to silence the chime tones simply enter your passcode. If the mains power is not restored you may not be able to set the alarm system. If the fault persists the standby battery will eventually run flat.
Display Messages (Cont.) Displays Description FIRE ALARM 07 17:30 01 Jan A fire alarm has occurred from a detection circuit (circuit 07). The internal sounder will generate a distinctive fire alarm tone and the external sounder is pulsed on and off. To silence the alarm simply enter your passcode. To reset the alarm simply enter your passcode again followed by [ESC]. FUSE BLOWN 01 17:30 01 Jan The auxiliary supply used for powering detection devices has blown its fuse.
System Records User Record User 01 Type Name Master 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Detection Circuit Record Circuit 01 02 03 04 05 06 07 08 38 Location Omit Chime P.Set A P.Set B P.
Detection Circuit Record (Cont.) Circuit Location Omit Chime P.Set A P.Set B P.
System Details Entry Time Exit Time Bell Delay Bell Duration Full Set By Part Set A by Part Set B by Part Set C by Reset by Allow set with line fault Set with mains off Remote signalling Downloading User Authorised Remote 1 Function Indicator Remote 2 Function Indicator Remote 3 Function Indicator Remote 4 Function Indicator Installer Information Installation Engineer: Alarm Company: Address: Telephone No.: Alarm Receiving Centre: Telephone No.