System information
26
Code Description
STR Synchronization Strobe, Wall Mount, Snap Base, 153075110cd 
STWC Synchronization Strobe, Ceiling Mount Snap Base, 15307595cd 
Product Codes
Code STR STWC
Description  Synchronised Strobes, Wall Mounted Synchronised Strobes, Ceiling Mounted
Standards UL Standard 1971 UL Standard 1971
Opperation
12/24 Vdc 15/1575/30/75/95/110/135/185 cd 15/1575/30/75/95/110/135/185 cd
Environmental
Operating Temperature  0°C to 49°C 0°C to 49°C
Humidity (Non Condensing)  0 to 93 %RH 0 to 93 %RH
Compatibility
Suitable for use with Menvier UL fire systems Menvier UL fire systems
Technical Specification
Horn Strobe Ratings
Horn Strobe Ratings per UL 1971 & UL 464 at 24 Vdc
UL Max Current* at 99 dB(A)
24 V dc  12 V dc
Mode  Regulated Voltage Range V dc  15  15/75  30  60  75  95  110  115  135  150  177  185  15  15/75
HS 8.0-33.0  0.082 0.095 0.102  0.148 0.176 0.197  0.242  0.282 0.125 0.159
HSC 8.0-33.0  0.082  0.102 0.141 0.148 0.176  0.197  0.242 0.282  0.125
Horn Strobe Ratings per UL 1971 & UL 464 at 24 V dc
UL Max Current* at 95 dB(A)
24 V dc  12 V dc
Mode  Regulated Voltage Range V dc  15  15/75  30  60  75  95  110  115  135  150  177  185  15  15/75
HS 8.0-33.0  0.073 0.083 0.087  0.139 0.163 0.186  0.230  0.272 0.122 0.153
HSC 8.0-33.0  0.073  0.087 0.128 0.139 0.163  0.186 0.230 0.272  0.122
Horn Strobe Ratings per UL 1971 & UL 464 at 24 V dc
UL Max Current* at 90 dB(A)
24 V dc  12 Vdc
Mode  Regulated Voltage Range V dc  15  15/75  30  60  75  95  110  115  135  150  177  185  15  15/75
HS 8.0-33.0  0.065 0.075 0.084  0.136 0.157 0.184  0.226  0.267 0.120 0.148
HSC 8.0-33.0  0.065  0.084 0.120 0.136 0.157  0.184  0.226 0.267 0.120
All strobe models are UL dual listed - meeting
both UL1638 and UL1971 requirements. As
dual listed appliances, these weatherproof
strobes are listed for outdoor applications
under UL 1638 as well as under UL 1971, the
Standard for Safety Signaling Devices for
Hearing Impaired. With an extended
temperature range of –31°F to 150°F (-40°C to
66°C), the weatherproof appliances meet or
exceed UL outdoor test requirements for rain,
humidity and corrosion resistance while
providing multiple strobe intensity options,
including the highest strobe ratings available
for area coverage per NFPA 72 strobe spacing
tables (up to 185 candela for wall mounting and
177 candela for ceiling mounting).
Dimensions - Wall
W
H
D
H (mm) W (mm) D (mm)
133 116 56
Dimensions - Ceiling
Dia
D
Dia (mm) D (mm)
166 34
STR & STWC - Synchronised Strobes