Technical data

496236 Issue 4 25
Zone 6 50 ENTER 0 ENTER Normal Alarm
1 ENTER PA
Prog O/P 51 ENTER 0 ENTER PIR set latch
1 ENTER Shock reset
Zone 1 in Part Set 52 ENTER 0 ENTER Normal Alarm
1 ENTER Entry/Exit
Part Set Alarm 53 ENTER 0 ENTER Full Alarm
Response 1 ENTER Internal sounder
Zone 3 54 ENTER 0 ENTER Normal Alarm
1 ENTER Entry/Exit
Zone 5 55 ENTER 0 ENTER Normal Alarm
1 ENTER Fire
30-second 64 ENTER 0 ENTER Enabled
Dual Ply 1 ENTER Disabled
Keypad 1 & 3 PA 68 ENTER 0 ENTER Disabled
1 ENTER Enabled
View Log 90 ENTER Press << to see earlier
events, >> for later events.
Walk Test 97 ENTER Trigger detectors. Press OMIT to exit test.
Load Defaults 98 ENTER Does not change access
codes
Leave Program 99 ENTER (See note 5.)
Notes:
1. n..n = the numbers of the zones. Key the zone number to toggle the zones on
or off. Pressing ENTER stores the zones selected. You cannot omit Entry/Exit
zone(s) in Full or Part set.
2. Program any zones not connected as "Not used".
3. The end user may change the user codes (see separate user guide).
4. Default user code 2 "0000" is inactive. Changing user code 2 back to "0000" at
any time makes the code inactive again.
5. If the internal sounder activates when you use this command then check the lid
tamper, bell tamper, and the global zone anti tamper.
To Re-enter Programming Mode
You can re-enter programming mode at any time when the panel is not set or
in alarm:
Key-in 0 then ENTER followed by the engineer access code.
All LEDs, except for Power, flash.
You are now in programming mode.
4. Programming