Technical data
24 496236 Issue 4
The panel beeps twice to show that it has accepted the command. All the
LEDs flash, and the panel is ready for the next command.
The panel gives a single error tone if you enter an incorrect command.
Re-enter the correct command.
3. Key in "99 ENTER" to leave programming mode when you have finished.
You will then be in user mode.
Engineer Program Command List
To change: Key-in: followed by: Notes
Zones omitted in 10 ENTER zone n..n ENTER LEDs ON for zones
Part Set* omitted (see note 1)
Chime 11 ENTER zone n..n ENTER LEDs ON for chime
(EE zone = zone 7)
Zones Not Used 15 ENTER zone n..n ENTER LEDs OFF for zone
not used (see note 2)
Engineer Code 20 ENTER new code ENTER 4 digits
User Code 1 21 ENTER new code ENTER 4 digits (see note 3)
User Code 2 22 ENTER new code ENTER 4 digits (see notes 3 & 4)
Silent Part set 35 ENTER 0 ENTER Audible
1 ENTER Silent
Zone 2 Entry 36 ENTER 0 ENTER Normal Alarm
Route 1 ENTER Entry Route
Auto Re-Arm 40 ENTER 1 ENTER Never rearm
2 ENTER Rearm once
3 ENTER Rearm twice
4 ENTER Rearm three times
Bell Time 42 ENTER 1 ENTER 90 seconds
2 ENTER 3 minutes
3 ENTER 10 minutes
4 ENTER 20 minutes
Entry time 43 ENTER 1 ENTER 10 seconds
2 ENTER 20 seconds
3 ENTER 30 seconds
4 ENTER 45 seconds
5 ENTER 1 minute
Exit time 44 ENTER 1 ENTER 10 seconds
2 ENTER 20 seconds
3 ENTER 30 seconds
4 ENTER 45 seconds
5 ENTER 1 minute
4. Programming