Operator`s manual

MODEL CS 208 v2
SPECIFICATIONS
MAY 2003
9
General: (0 dBu .775v RMS)
Dimensions 16.5 x 15.2 x 5 (419 x 386 x 127 mm)
Weight with no batteries 19 lbs. (8.6 kg)
with alkaline cells 23lbs. (10.4 kg)
Overall distortion (THD + N) < 0.01% (0.003% typ.)
Equivalent input noise (150 20-20kHz) -129.5 dBu
(150 AWTD) -131.2 dBu
Power Requirements:
External: 10v - 25v operating range.
Consumption with all channels on is 630 mA at 12v DC < 8 watts (410 mA at 18v DC)
Estimated battery life with 12v, 8 AH lead acid battery > 10 hours.
12v, 12 AH lead acid battery > 15 hours.
18v, 14 AH alkaline cells > 15 hours.
(Ni-CAD D cells are 1/3 the capacity of alkaline cells.)
XLR - 4M:
1 = Ground (-)
2 = N/C
*3 = Battery charge (+)
4 = External in (+) * Do not connect if rechargeable batteries are not installed.
Internal Power: 12 Dalkaline cells
PPM
VU Nordic
Battery test: + 18v DC = +2 +3 Full Scale (Last mark)
+ 12v DC = -6 0 +4
+ 10.5v DC= -8 -1 +2
BNC light: +12v out, 500 mA max. (1815 bulb 180 mA).
Power on LED: Turns off when the voltage is 11v or less.
Power cut off voltage: 10v DC (internal supply switches off).
48v Phantom: 48v +/- 1v.
12v T: 12v +/- 1v.