Event Description 
BEAM PAIR ####  First activation of a beam pair zone number #### 
BELL BOX TAMPER  Not used 
BELL FUSE  Bell fuse tripped 
BELL TAMP OMIT  Bell tamper omitted after confirmation timer has expired 
BELL TESTED:-  Bell tested for wards 
BELLS ACTIVE:-  Bell active for wards 
CHANGE CODE ###  User code for user ### changed 
CHANGE TAG ###  User tag changed for user ### 
CHNG CODE ####  User code changed for user #### 
CHNG TAG ####  User tag changed for user #### 
CNFG CHANGE ####  Configuration change for user #### 
CODE ####  Passcode entered for user number #### 
CODE LOCK # OFF  Code lock number # is off 
CODE LOCK # ON  Code lock number # is on 
CODE LOCKED ####  User number #### attempted to use their passcode whilst locked-out 
CODE TAMPER  Keypad locked out for 5 minutes due to invalid entry of passcode 
COMMS FAILED  On-board modem failed to communicate with ARC 
COMMS TEST CALL  Communications test call started 
CONFIG CHANGE ##  Configuration change for user ## 
DATE CHANGED AT  System date changed at 
DATE CHANGED TO  System date changed to 
DEFAULT USER  User 01 (manager) code defaulted 
DEFAULT USER ####  Not used 
DEFERRED SET:-  Deferred set on wards 
DL DISCONNECT FL)  Downloader disconnected incorrectly 
DL DISCONNECT OK  Downloader disconnected 
DURESS CODE ####  Duress alarm from user number #### 
ENG HW DEFAULTED  Panel factory reset 
ENGINEER ARRIVES  Engineer is logged on the system 
ENGINEER DEPARTS  Engineer is logged off the system 
ENTRY TIME-OUT:-  Entry mode timed out for wards 
ENTRY ZONE ####  Entry mode started from zone number #### 
EXIT CANCELLED:-  Exit mode cancelled for wards 
EXIT STARTED:-  Exit mode started for wards 
EXT LINE FAULT  Not used 
EXT LINE RESTORE  Not used 
FACTORY RESTART  Factory default loaded 
FAULT 4K4 ####  Zone has 4k4 fault 
FIRE ALARM ####  Fire alarm from zone number #### 
FIRE RESET:-  Fire Alarm reset 
FIRE WARDS:-  Fire alarm on wards 
FIRST KNOCK ####  First activation of zone number #### (zone with Double-Knock attribute) 
FROM REMOTE #,##  Not used 
HI-SECURITY SET:  Wards set using “High Security” feature 
ID LOOP RESTORED  Short circuit cleared from ID loop 
ID LOOP SHORTED  ID loop is short-circuited 
KEYPAD PANIC ###  Panic alarm raised from keypad (buttons 1 and 3 pressed) 
KEYSWITCH ###  Keyswitch zone #### activated 
LOCAL ON LINE  Local connection with Downloader 
LOCAL SERV CALL  Local connection with Downloader 
LOCAL SERV END  Not used 
LOCKSET #### ON  Lock set zone #### activated 
LOCKSET #### OFF  Lock set zone #### deactivated 
LOCKSET WARD ON  Lockset for ward enabled 
MAIN POWER ON  Mains power applied to control panel 
MAINS POWER OFF  Mains power removed from control panel 
MASK ALRM S ####  Mask set alarm 
MASK ALRM U ####  Mask unset alarm 
MASK FLT S ####  Zone #### masked when set 
MASK FLT U ####  Zone #### masked when unset 