User`s guide
42 
Option 2-0-2: 
Setting Up Auto-Set 
Timers 
Use this option to make the control unit set 
or unset selected wards at specified times. 
You can allocate each auto-set timer to 
one or more wards, which the control unit 
sets and unsets at the times you chose. 
For each auto-set timer you can specify a 
description, a switch on/off (set/unset) time 
and day of the week, and Exceptions. 
When a timer reaches the “on” time for an 
event the control unit operates the keypad 
sounders
1
 and then sets the allocated 
ward(s). Note that the control unit will not set 
any ward where there is an active detector. 
During the warning time a user can defer 
setting for a short period by entering their 
user code
2
. 
When a timer reaches an “off” time, the 
control unit unsets the allocated ward(s). 
User 2 Menu 0 
2:Auto Sets 
1. Press [ to select this option. 
Timers 2 
Auto-Sets 
2. Use | or ¬, or press 2 to select Auto 
Sets, then press [. 
Auto-Set 01 
3. Use | or ¬, or press a hot key (01 to 
32) to select the auto-set timer to 
edit. (The display shows the timer 
number at the top right.) 
1
 Engineer menu option 1-5-2-32 sets the length of the warning time. 
2