10 
Option 1-5: Enabling Chimes 
  This option enables you to select which of 
your wards (if any) use the chime feature. In 
a ward with this feature enabled, zones that 
have a Chime Tone attribute (User option 2-
5) and are in a selected ward will generate a 
chime tone when activated. The wards then 
remain chime-enabled until you deselect 
them with this option. 
A zone may generate one or more chime 
tones, depending on the Chime Tone 
attribute selected in User option 2-5: 
Chime tone 1  single chime 
Chime tone 2  double chime 
Chime tone 3  triple chime 
The chime occurs only at keypads and 
extension loudspeakers assigned to the 
same ward(s) as the zone. 
When a chime occurs, keypads display the 
zone number if configured by the Chime 
Visible setting in Engineer option 1-9-1-08. 
User 1 Menu 5 
Enable Chime 
1. Press [ to select this option. 
Chime on wards: 
Ward > 1*...... 
2.  Use the numeric keys to select the wards 
you want to have chime enabled, then 
press [. Any ward numbers shown will 
be chime enabled. (A “*” indicates that 
the ward will not be chime enabled. A “.” 
Indicates that either you have no access 
to the ward, or the ward is not 
programmed.) 