User guide

5. Testing
Page 50 496929
Testing Outputs (Commands 91-96)
You may test parts of the system by entering commands at the keypad. To
carry out a test make sure the system is in programming mode and then key
in one of the following commands. Press Y to end each test:
91Y To test output 1 (usually the external sounder/bell).
92Y To test output 2 (usually the strobe output).
93Y To test output 3.
95Y To test the keypad sounder.
Engineer Walk Test (Command 97)
Allows the engineer to test all devices on the system.
1. Enter programming mode.
2. Key in 97 Y
The display shows:
97: Walk Test
3. Open and close each alarm and tamper contact in turn.
The system gives a chime tone each time you open and close a detector
contact. The displays shows: "A:Zone:" and the zone number of every
detector you have tested (note that the display shows each zone number
for one second, in sequence). If you also test the tampers on each zone
the display shows the letter "T" against each zone number.
4. Press X to stop the walk test.
Note that the Engineer's walk test allows you to test all zones including PA
zones, zone tampers, and control unit and bell tampers. The user's walk test
does not allow you to test PA, Fire, 24Hr, Technical zones, or tampers.