User guide
4. Programming
Page 44 496929
90 - 97: See “5.Testing”
98: Load Full Defaults
Use this Command to load default values for all Commands.
1. Enter programming mode (if you are not already there).
2. Key in 98 Y at the keypad.
The display shows:
Load default
3. Press 1. (You can press X to stop the procedure if you change your mind
at this stage.)
4. Press Y.
The keypad gives a double confirmation tone and the system loads the
factory default Command values, erasing all previously programmed
values.
Note: The log is protected and cannot be erased by the Installer.
99: Leave Programming Mode
To leave programming mode:
1. Key in 99 Y at the keypad.
The display shows:
Exit Eng?
2. Press Y.
The display shows:
Checking System
and after a few seconds the control unit
resets itself and returns to user mode.
If any 24 hour, Fire, PA or Technical zones or any tamper switches are active
when you try to leave
programming mode then the keypad gives an error tone and displays all the
faults.
Clear the faults shown on the display and press Y. Repeat steps 1 and 2 and
the control unit should leave programming mode.