4. Programming
496929 Page 41
Output Type
Option
00 Bell. - The control unit operates this output during an alarm. Use
Command 41 to control bell delay and 42 to control bell duration.
01 EE Follow. - This output is active when the entry or exit time starts
and deactivates at the end of the entry/exit time, or if the entry/exit
time is terminated. The output can be used for a separate entry/exit
buzzer. Note that the output does not give a tone during part set if the
exit mode is silent set or instant set.
02 Armed lamp. - The output is active continuously while the system is
full or part set.
03 PIR Set Latch. - This output is active when the system is set and
deactivates when the system is unset or an alarm condition occurs.
The output will also activate for one second when a reset is performed
or the control unit leaves programming mode. In addition, the output is
active during a walk test.
04 Shock Reset. - This output is used to reset shock sensors, (for
example the ‘Viper or Trapper’). The control unit triggers the output at
the start of the exit period. The output remains active for a fixed time
of five seconds.
05 Walk Test. - This output is active during both engineer and user walk
test and in the period between silencing the system and resetting the
system. This output type is used on movement detectors which have
the facility to switch off the walk test LED in any state other than a
walk test.
06 Ready Lamp. - (System is Clear to Set) This output is active when the
system is unset, and if there are no faults. The output is inactive when
the system is full or part set, during any alarm, or if a circuit fault
prevents setting (Final Door and Entry Route zone types are ignored).
Note: The output will also be active when the control unit is in programming
mode.
07 24 Hour alarm. - This output will become active if a zone designated
as ’24 Hours’ is violated. The output deactivates when the system is
disarmed.
08 Strobe. - In an alarm the system operates the output. The output
remains active until the user disarms the system.
09 Smoke Reset. - This output is designed to be connected to low
voltage smoke detector reset terminals. The control unit operates the