User guide

4. Programming
Page 38 496929
to 1 any Entry Route zones included in part set B will act as Final Exit zones
during part set B.
62: Level B Exit Mode
Command 62 specifies the exit mode for Level B.
Option
0 Low Tone. Timed set with the exit tone fixed at half volume.Use
Command 65 to select the exit time.
1 Instant Set (no exit tone)
2 Silent Set. (Timed Set with no exit tone) .Use Command 65 to
program the Exit time.
3 As A. The exit mode chosen for Level A (whole system) is also
applied to this level.
Note: The keypads give a double beep confirmation tone at the end of all
setting modes.
63: Level B Alarm Response
Command 63 specifies the alarm response for Level B.
Option
0 Keypad sounders.
1 Internal sounders and keypad sounders
2 Local alarm (internal and external sounder only).
3 Full alarm (communication outputs and internal/external sounders).
64: Level B Entry Time
This Command sets the entry time for Level B. See “Programming
Commands” for options.
65: Level B Exit Time
This Command sets the exit time for Level B. See “Programming Commands”
for options.
70: Level C Final Exit Operation
Command 70 controls how the system will treat Final Exit zones in part set
Level C. When the Command option is set to 0 any Final Exit zones included
in part set Level C will continue to act as Final Exit zones during part set Level
C. When the option is set to 1 any Final Exit zones included in part set Level
C will act as Normal Alarm zones during part set C.