User guide
4. Programming
496929 Page 35
the entry timer. The user completes entry by unsetting the system in
the normal way.
Note: If an intruder opens the final exit door without first unlocking the
lockswitch then the control unit immediately starts an alarm.
If you select Timed (options 0), Terminate (option 1), or Final Door (option 2)
exit modes the system allows a seven second settling time after pressing an
exit terminate button or closing a final door.
40: System Auto Re-Arm
This Command lets you program the number of times that the system will re-
arm when the bell delay expires. The system re-arms all closed zones. Select
option 0 to make the system never re-arm (the system will go into alarm once
only). Select options 1 to 4 to make the system re-arm once, twice, three
times or always.
Use this Command in conjunction with Command 35 - First Circuit Response.
If the system has rearmed, then when a user enters the system through the
entry route the control unit will give an audible internal alarm in place of the
normal entry tone.
41: Bell Delay
When the system is set and (for example) an intruder violates a zone, then
the system waits for the programmed Bell Delay before operating the external
sounder. The system then operates the external sounder for the programmed
Bell Duration. See “Programming Commands” for the Command options.
42: Bell Duration
This Command lets you set the length of time the system will operate the
external sounder during an alarm. See “Programming Commands” for the
Command options.
43: Level A Entry Time
This Command lets you set the Entry Time for Full Set. See “Programming
Commands” for the Command options. The time starts when a user opens
any Final Exit zone.
44: Level A Exit Time
This Command lets you set the Exit Time for Full Set. See “Programming
Commands” for the Command options.
45: Entry/Exit Tone Volume
Use this Command to set the volume of entry/exit tones from the internal
sounder. If you select option 0 then the internal sounder gives no entry/exit
tones. If you select option 1 then the internal sounder gives quiet entry/exit