User guide
4. Programming
Page 34 496929
38: System Tamper Reset
This Command allows you to choose whether the customer can reset the
system after a tamper alarm. This facility is independent of that offered by
Commands 31 and 33. If you select option 0 (customer) then the user can
reset the system after a system tamper alarm providing no fault exists. If you
select option 1 (engineer) then you must enter the engineer access code at a
keypad to reset the system after a system tamper alarm.
39: Level A Exit Mode
Use this Command to select the exit mode for Level A (Full Set).
Note: The keypads give a double beep confirmation tone at the end of all
setting modes.
Option
0 Timed. Use this option EITHER if the user completes setting the
system by pushing an exit terminate button connected to a keypad OR
if no exit terminate button is connected, and the system sets after a
delay selected using Command 44.
1 Terminate. Use this option if the user completes setting the system by
pushing an exit terminate button connected to a keypad. Note that the
exit time is infinite in this option.
2 Final door set. Use this option to complete setting the system by
closing a door fitted with a Final Exit zone detector. Note that the exit
time is infinite in this option.
3 Lock Set. To use this method you must install a lock switch with the
contacts connected to the ET terminals of a keypad. This facility is
available on keypad software version 1.4.2 onwards.
Note: 1. The lockswitch contacts must be closed circuit with the lock
unlocked.
2. Do not connect more than one lockswitch (or any other device) to the
keypad ET terminals.
To set the system the user first enters their access code at a keypad.
The control unit starts the exit tone. Note that the exit time is infinite in
this option. The user then closes the final exit zone and turns the key
in the lock switch to “locked”. The system sets seven seconds after
the lock switch contacts open (detector settling time), and changes the
final exit zone to a Normal Alarm zone.
To unset the system the user turns the lock switch to “unlocked”
(closing the lock switch contacts). The keypads start a continuous
tone. When the user opens the final exit zone the control unit starts