4. Programming
Page 32 496929
28: Status Display
Use option 1 of this Command if you do not wish to show keypad displays
permanently. The keypad displays “Level Set” for 180 seconds after the user
sets the system and then reverts back to the time and date display. Use this
option when installing a system in the U.K.
When set to option 0 the keypad displays “Level Set” the whole time that the
alarm system is set.
Use option 2 to make the keypad display revert to time and date 30 seconds
after any event. Note that if you use this option the s and f LEDs also
operate for only 30 seconds.
29: Entry Alarm Delay Time
This Command determines what the system will do if a user strays from an
entry route zone during entry. ( If this Command is enabled, the system will
fulfil the requirements of EN 50131-1.)
Use option 0 to make the system generate an immediate alarm if the user
strays from an entry route zone during entry.
If you use option 1 and the user strays from the entry route during entry time
then the system waits until the end of the entry time and then adds 30
seconds before raising a full alarm. From the entry stray the internal sounder
will operate to alert the user that they have made a mistake and have time to
unset the system.If the user enters an access code before the end of the entry
time or within the additional 30 seconds then the user can reset the system.
30: Silent or Audible PA
This Command selects how the system responds when a PA zone operates.
Option
0 (Audible PA) The system operates the sounders and, if a
communicator is fitted, sends a PA message to the ARC.The keypad
displays the PA zone when a user disarms the system.
1 (Silent PA) The sounders stay silent. If a communicator is fitted the
system sends a PA message to the ARC.The keypad displays the PA
zone when a user disarms the system.
31: Zone Tamper Reset
Use this Command to ensure that the system complies with Scandinavian
requirements for resetting zone tamper alarms while the system is unset.
Use option 0 to allow user reset after a zone tamper.
Use option 1 to enforce engineer reset. The user can silence the alarm, but
the engineer must reset the system by entering the engineering access code,
or by using anti-code or remote reset.