User guide
4. Programming
496929 Page 31
21: Zone Configuration
This Command allows you to select the wiring type of the zone connectors on
the main PCB. The options available are:
Option
0 Eight Closed circuit zones with global anti tamper on control unit.
1 Eight Fully Supervised Loop (FSL) zones on control panel.
See Chapter 3 for wiring details.
22: Loudspeaker Chime
A user may find that the chime tone from the keypads is not loud enough. If
so, then use Command 22 option 1 to make the internal sounder also give the
chime tone. To alter the volume of the tone from the internal sounder enter a
digit in the range 1 to 9. 1 is quietest, 9 is loudest. The internal sounder
demonstrates the volume of the tone when you enter the digit.
23: RedCare Reset
Option 1 enables RedCare Reset, which is designed to operate with the plug-
by communicator lead.
Note: You must set System Reset to Engineer (Command 33 option 1) to
ensure RedCare Reset works correctly.
After an alarm the user keys in their access code to silence the alarm, but
cannot reset the system. The first to alarm display and Service LEDs remain
visible. The user contacts the ARC, who verifies the user's identity. The ARC
sends a signal back to the control unit. The Service LED goes dark and the
end user can now reset the system with any valid access code, providing that
there are no faults.
Use option 0 (the default) to disable the function.
25: Continuous Sounder
Option 0 of this Command makes the internal sounder follow the external bell
delay and duration times. Option 1 makes the internal sounder continue after
the external bell times out.
27: Exit Fault External Sounders
When programmed with option 0 the system operates the internal sounders if
the user tries to exit while a zone is still violated (for example a door is not
shut). When programmed with option 1 the system operates the external
sounders as well as the internal sounders.