User guide

4. Programming
Page 30 496929
X3 Double Knock (2) Zones with this attribute will cause an alarm
condition only if one or more sensors generate two alarms events
within a five minute time window, or if one zone remains open for
more than 10 seconds. Programming a zone as ‘Double Knock’ is a
way of reducing false alarms caused by environmental changes, but is
not normally recommended.
Note: ‘Double Knock’ is available only for Normal Alarm and Entry Route
zone types.
X4 Omit Allow (O) When applied to a zone, this attribute allows the user
to omit the zone.
B Level B When applied, the zone will be armed when the user selects
Level B.
C Level C When applied, the zone will be armed when the user selects
Level C.
D Level D When applied, the zone will be armed when the user selects
Level D.
X7 Sensitivity When you use this Command you must also enter an extra
digit in the range 1 to 6 in order to set the sensitivity of the shock
sensor. 1 is least sensitive, 6 is most sensitive. Note that to use this
attribute you must make one of zones 1 to 4 a shock analyser type.
To adjust the sensitivity you must enter the complete Command, for
example to change the sensitivity to 3 you must key in: X7 + 3.
20: Change Engineer Code
To change the Engineer access code:
1. Make sure you are in programming mode.
2. Key in 20 and press Y.
The display shows:
20:Code
3. Key in a new four digit Engineer access code.
The display shows:
20:Code ****
4. Press Y.