User guide
4. Programming
496929 Page 29
To set Level A do not assign a Keyswitch zone to levels B, C or D. To
set any other level assign the Keyswitch zone to a single level.
11 Momentary (KM) - Use this zone type to connect a momentary
keyswitch to a single zone.
12 Fixed (KF) - Use this zone type to connect a fixed position keyswitch
to a single zone.
13 Anti-Mask Zone (AM) - Note This zone type is for use in EN50131
Grade 3 systems only and is not applicable
on the 9651 control
panel.
14 Forbikobler (FB) - This zone type is a Scandinavian entry/exit zone.
Use this type on zones connected to stand alone external keypads or
access controllers. The zone operates as a normal entry/exit zone but
when triggered by the external keypad during the exit time the control
unit stops the exit time and sets the system. If the zone is triggered
while the system is set then the control unit starts the entry time.
Zone Attributes
Specific zone types can have one or more attributes programmed by the digit
after the zone Command and type. (To remove an attribute, key in the
attribute digit again.)
Option
X1 Chime (C) When enabled by the user, the system gives a non-alarm
warning tone when any zones programmed as ‘Chime’ are opened.
This facility operates only while the system is unset.
Note: 1. ‘Chime’ is available only for Normal Alarm, Final Exit, Entry Route
and Shock Analyser zone types.
2. To make chime available from the keypad sounders but not the
internal sounder then program Command 22 with option 0.
X2 Soak Test (S) Use this zone attribute if you want to place under long
term test a detector that you suspect is giving false alarms. Zones with
this attribute are disabled for 14 days after you return the control unit
to user mode. If the zone is opened while the system is set then the
Service LED glows and the control unit logs the event as a “Soak Test
Fail Zn” (n is the zone number) without sounding any bells or starting
signalling. The Service LED stays alight until the Engineer resets the
system. After midnight on the 14th day the control unit returns the
zone to normal use.
Note: Soak test is available only for Normal Alarm, Entry Route, Technical
and Shock Analyser zone types.