User guide

4. Programming
Page 26 496929
Programming Command Reference
0: Country Defaults
Use this Command to select the country and PTT defaults (to select language
see Command 126).
Note: 1. If you select options
X
5,
X
6 or
X
7 (Norway, Sweden or Denmark)
then the control unit also changes the method of entering programming
mode. See “Entering Programming Mode” at the beginning of this
chapter.
2. This Command loads default access codes and programming options.
See “Programming Commands” for details of the options available.
01 - 08 : Zone Programming
The zone programming Commands 01 to 08 take three or more digits. The
first two digits describe the zone type, subsequent digits describe the zone
attributes.
When you key in the zone number and press Y the display shows the zone
number and any text caption for the zone. At this point you can edit the zone
text (see next page). Press Y again to start entering the zone types and
attributes. When you have entered the zone type and attributes press Y once
more to store the changes.
Zone Names
When you key in the zone number and press Y the display shows the current
zone name with a flashing cursor under the first letter. Enter letters from the
keypad one at a time by pressing a number key repeatedly until the display
shows the letter you want. You may already be familiar with typing out short
messages on a mobile phone using the same sort of system. Figure 17
shows which letters are assigned to each key. Press C to move the cursor to
the next space for a new letter.
If you make a mistake press C or D to move the cursor over the letter you
want to change, and key in the new letter. If you want to delete a name
completely press D to move the cursor under the extreme left hand character
of the name. Press D again. The display clears the old name.
The system can store a maximum of 12 characters per name, including
spaces and punctuation marks.
When you have finished entering the user name press Y.