User guide

4. Programming
496929 Page 25
Re-entering Programming Mode
You can go back into programming mode whenever the system is unset and
not in alarm:
1. Key in 0 followed by the Engineer’s code (default 7890).
The display shows:
Installer Mode
You are now in programming mode.
Restoring the Access Codes (1st stage reset)
If the user and/or engineer codes are lost, then:
1. First remove mains power and then open the case and disconnect the
battery.
2. Identify the NVM Reset pins and Kick Start pins on the main pcb (see
Figures 3).
3. Short the NVM Reset pins together using a small wire link. Short the Kick
Start pins together with another small wire link.
4 Reconnect the battery.
5. Remove the shorts from the NVM Reset pins and Kick Start pins.
The control unit loads the factory default access codes:
User 1: 1234, Engineer: 7890.
6. Close the control unit and apply mains power.
7. Carry out an engineer reset.
Restoring All Factory Default Programming
If you wish to restore all factory default options then:
1. Enter programming mode (if you are not already there).
2. Key in 98 Y at the keypad.
The display shows:
Load default
3. Press 1 Y at the keypad.
4. Press Y.
The keypad gives a double confirmation tone and the system loads the
factory default Command values, erasing all previously programmed
values.
Note:The log is protected and cannot be erased by the Installer.